Reference Manual
00809-0100-4665, Rev AA
August 2010
B-5
Rosemount 8732
InMetro - Brazil
E2 InMetro Flameproof Certificate No.: NCC 5030/08
BR-Ex de IIC or BR-Ex de [ia] IIC T6 (-50 °C Ta +60 °C)
with LOI (-20°C Ta +60 °C)
Vmax = 250 V AC or 42 V DC
EB InMetro Flameproof Certificate No.: NCC 5030/08
BR-Ex de IIB or BR-Ex de [ia] IIB T6 (-50 °C Ta +60 °C)
with LOI (-20°C Ta +60 °C)
Vmax = 250 V AC or 42 V DC
KOSHA - Korea
E9 KOSHA Flameproof Certificate No.: 2008-2094-Q1X
Ex de IIC or Ex de [ia] IIC T6 (-50 °C Ta +60 °C)
with LOI (-20°C Ta +60 °C)
Vmax = 250 V AC or 42 V DC
EK KOSHA Flameproof Certificate No.: 2008-2094-Q1X
Ex de IIB or Ex de [ia] IIB T6 (-50 °C Ta +60 °C)
with LOI (-20°C Ta +60 °C)
Vmax = 250 V AC or 42 V DC
SENSOR APPROVAL
Table B-1. Sensor Option Codes(1)
(1) CE Marking is standard on Rosemount 8705, 8711, and 8721.
Approval
Codes
Rosemount 8705
Sensor Rosemount 8707
Sensor Rosemount 8711
Sensor
Rosemount
8721
Sensors
For Non-
flammable
Fluids
For
Flammable
Fluids
For Non-
flammable
Fluids
For
Flammable
Fluids
For Non-
flammable
Fluids
For
Flammable
Fluids
For Non-
flammable
Fluids
NA • •
N0 •••
ND •••••••
N1 • • • •
N5 ••••••
N7 • • • •
ND • • • •
NF • • • •
E1 • • • •
E2 • • • •
E3 • • • •
E5(2)
(2) Available in line sizes up to 8 in. (200 mm) only.
• • • •
E8 • • • •
E9 • • • •
EB • • • •
EK • • • •
EM • • • •
EP • • • •
KD • • • •