Rosemount 8732

Reference Manual

00809-0100-4665, Rev AA August 2010

NOTE

The number of devices on a Profibus segment is limited by the power supply voltage, the resistance of the cable, and the amount of current drawn by each device.

Transmitter Wiring Connection

To connect the 8732 to the Profibus PA segment, complete the following steps.

1.Ensure that the power source and connecting cable meet the requirements outlined above and in “Field Wiring” on page 2-7.

2.Turn off the transmitter and power sources.

3.Run the Profibus PA cable into the transmitter.

4.Connect PA to Terminal 1.

5.Connect PA to Terminal 2.

NOTE

Profibus PA signal wiring for the 8732 is not polarity sensitive.

Figure 2-5. Profibus PA Signal Connections

Refer to Figure 2-5 on page 2-8.

PA signal

PA signal

2-8

Page 16
Image 16
Emerson Rosemount 8732 manual Transmitter Wiring Connection, Profibus PA Signal Connections Refer to -5 on