Reference Manual

00809-0100-4665, Rev AA August 2010

Rosemount 8732

ORDERING

INFORMATION

Table A-1.Rosemount 8732E/ Profibus PA Ordering Information

Model

 

Product Description

8732E

 

8732E

 

Magnetic Flowmeter Transmitter

 

Transmitter Style

 

 

Standard

 

 

Standard

S

 

Standard

Transmitter Mount

 

 

Standard

 

 

Standard

T

 

Integral Mount

R

 

Remote Mount for 2 in. pipe or panel (includes CS mounting bolts and 304 SST bracket)

Transmitter Power Supply

 

 

Standard

 

 

Standard

1

 

AC Power Supply (90 to 250 V AC, 50-60Hz)

2

 

DC Power Supply (12 to 42 V DC)

Outputs

 

 

 

Standard

 

 

Standard

P

 

Profibus PA fieldbus digital electronics with FISCO Intrinsically Safe Output

 

 

 

8732E

 

Expanded

 

 

 

U

 

Profibus PA fieldbus digital electronics (Available with approval code NA only)

 

Conduit Entry

 

 

8732E - 2 Conduits

 

 

Standard

 

 

Standard

1

 

1/2 - 14 NPT

Expanded

 

 

 

 

2

 

CM20(1)

 

3

 

PG 13.5(1)

 

3 Conduits

 

 

 

Standard

 

 

Standard

4

 

1/2 - 14 NPT

Expanded

 

 

 

 

5

 

CM20(1)

 

6

 

PG 13.5(1)

 

Safety

Approvals(2)

 

 

Standard

 

 

Standard

NA

 

CE Marking, no hazardous location approval

FM & CSA

 

 

 

 

Standard

 

 

Standard

N0

 

FM Class 1 Div 2 for non-flammable: CSA Class 1 Div 2

N5

 

FM Class 1 Div 2 for flammable fluids

E5

 

FM Class 1 Div 1, explosion-proof

ATEX

 

 

 

 

Standard

 

 

Standard

ED

 

ATEX flameproof Ex de IIB T6, and ATEX Dust Approval; Ex de [ia] IIB T6 with IS Output

ND

 

ATEX Dust Ex tD A20 IP66 T100 °C

Expanded

 

 

 

 

E1

 

ATEX flameproof Ex de IIC T6, and ATEX Dust Approval; Ex de [ia] IIC T6 with IS Output

 

N1

 

ATEX Type Ex nA nL IIC T4 or Ex nA nL [ia] IIC T4

 

A-9

Page 83
Image 83
Emerson Rosemount 8732 manual Ordering Information