Rosemount 8732

Reference Manual

00809-0100-4665, Rev AA August 2010

 

NOTE

 

Be sure the calibration number reflects a calibration to a Rosemount

 

reference transmitter. If the calibration number was generated by a means

 

other than a certified Rosemount flow lab, accuracy of the system may be

 

compromised.

 

 

 

If your sensor is not a Rosemount sensor and was not calibrated at the

 

Rosemount factory, contact your Rosemount representative for assistance.

 

If your sensor is imprinted with an eight-digit number or a k-factor, check in

 

the sensor wiring compartment for the sixteen-digit calibration number. If

 

there is no serial number, contact the factory for a proper conversion.

Damping

 

Adjustable between 0.0 and 256 seconds. This parameter is configured in the

 

Transducer Block.

 

Damping allows selection of a response time, in seconds, to a step change in

 

flow rate. It is most often used to smooth fluctuations in output.