Reference Manual
Rosemount 8732
KENT VERIFLUX VTC SENSOR
Veriflux VTC Sensor to 8732 Transmitter
Connect coil drive and electrode cables as shown in Figure
Figure E-16. Wiring Diagram for Kent Veriflux VTC Sensor and Rosemount 8732
Table E-17. Kent Veriflux VTC Sensor Wiring Connections
KENT VERIFLUX VTC | ROSEMOUNT 8732 | ||
| SENSOR |
| TRANSMITTER |
Electrode Connections |
| ||
3 4 | 2 |
|
|
SIG SIG 5 6 | 1SCR |
|
|
1 | OUT |
|
|
2 |
|
| |
| 5+ 6 SCR | 1 2 - | Fuse |
|
| ||
| OUT |
|
|
| Coil Connections |
|
Rosemount 8732 |
| Kent Veriflux VTC Sensors | ||||
1 |
|
| 2 | |||
2 |
|
| 1 | |||
|
|
|
|
|
| SCR OUT |
|
|
|
|
| ||
17 |
|
| SCR OUT | |||
18 |
|
| SIG1 | |||
19 |
|
| SIG2 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This is a pulsed DC magnetic flowmeter.
Do not connect AC power to the sensor or to terminals 1 and 2 of the transmitter, or replacement of the electronics board will be necessary.