Reference Manual

00809-0100-4665, Rev AA August 2010

Rosemount 8732

Index

Parameter Name

Description

78

EP_TRIG_COUNTS

Number of EP measurements that must be

 

 

above the trigger level to set empty pipe.

79

EP_TRIG_LEVEL

Empty Pipe Trigger Level.

80

EP_VALUE

Value of the Empty Pipe measurement.

 

 

(Same scale as EP_TRIG_LEVEL).

81

ELECT_TEMP

Compensated electronics temperature with

 

 

status.

82

TEMPERATURE_UNITS

See section Engineering Units for supported

 

 

unit codes.

83

DSP_SOFTWARE_REV_NUM

DSP software Rev Number - major, minor,

 

 

build.

84

PERFORM_AUTO_ZERO

Perform auto zero calibration routine

 

 

Note1: Writing anything but a 2 has no effect.

 

 

Reads will always return a 1 or a 2.

85

PERFORM_ELECTRONICS_TRIM

Perform input trim calibration routine

 

 

Note1: Writing anything but a 2 has no effect.

 

 

Reads will always return a 1 or a 2.

86

FLOW_TUBE_TAG

Text string identifier of sensor.

87

FLOW_TUBE_SERIAL NUMBER

Sensor serial number from physical tag on

 

 

sensor.

88

LINER_MATERIAL

Enumerated string indicating liner material of

 

 

installed sensor.

89

ELECTRODE_MATERIAL

Enumerated string indicating electrode

 

 

material of installed sensor.

90

ELECTRODE_TYPE

Enumerated string indicating electrode type of

 

 

installed sensor.

91

FLANGE_TYPE

Enumerated string indicating flange type of

 

 

installed sensor.

92

FLANGE_MATERIAL

Enumerated string indicating flange material

 

 

of installed sensor.

93

Reserved

Reserved.

94

DIAG_SNR_5HZ

Signal to Noise ratio at 5 Hz.

95

DIAG_SNR_37HZ

Signal to Noise ratio at 37.5 Hz.

96

Reserved

Reserved.

97

LINE_NOISE

50/60 Hz line noise

98

DIAGNOSTIC_HANDLING

On/off handling for diagnostics.

99-108

Reserved

Reserved.

109

SP_CONTROL

Signal Processing Control Code.

110

SP_NOISE_MODE

Noise Mode.

111

SP_NUM_SAMPS

Signal Processing Number of Samples.

112

SP_PERCENT_LIMIT

Signal Processing Percent Limit

113

SP_TIME_LIMIT

Signal Processing Time Limit

114

LICENSE_KEY

Key/password to enable diagnostic features.

 

 

Any changes to the licensing will be shown in

 

 

the LICENSE_STATUS parameter.

115

LICENSE_STATUS

Bit mask that shows which diagnostics are

 

 

licensed.

116

METER_VERIF_TEST_SCOPE

Scope of the Flowmeter Verification Test.

 

 

Note: This parameter needs to be configured

 

 

before the Meter Verification is started via the

 

 

PERFORM_METER_VERIFY parameter.

G-3

Page 159
Image 159
Emerson Rosemount 8732 manual Eptrigcounts