Rosemount 8732

Reference Manual

00809-0100-4665, Rev AA August 2010

For Rosemount 8732E transmitters:

IEC 60079-0: 2004

IEC 60079-0: 2007

IEC 60079-1: 2007

IEC 60079-7: 2006

IEC 60079-11: 2006

IEC 60079-15: 2005

IEC 61241-0: 2004

IEC 61241-1: 2004

NOTE

For intrinsically safe (IS) outputs on the 8732E output option code B, F, or P must be selected.

IS outputs for Class I, Division 1, Groups A, B, C, D. Temp Code – T4 at 60°C IS outputs for Ex de [ia] IIB or IIC T6

NOTE

For the 8732E transmitters with a local operator interface (LOI), the lower ambient temperature limit is -20 °C.

North American Certifications

FM Approvals

N0 Non-incendive for Class I, Division 2, Groups A, B, C, and D non-flammable fluids (T4 at 60 °C: -50 °C Ta 60 °C), and Dust-ignition proof Class 2/III, Division 1, Groups E, F, and G (T5 at 60 °C) Hazardous locations; Enclosure Type 4X

N5 Non-incendive for Class I, Division 2, Groups A, B, C, and D flammable fluids (T4 at 60 °C: -50 °C Ta 60 °C), and Dust-ignition proof Class 2/III, Division 1, Groups E, F, and G (T5 at 60 °C) Hazardous locations; Enclosure Type 4X

Requires sensors with N5 Approval

E5 Explosion-proof for Class I, Division 1, Groups C and D (T6 at 60 °C), and Dust-ignition proof Class 2/III, Division 1, Groups E, F, and G (T5 at 60 °C), Non-incendive for Class I, Division 2, Groups A, B, C, and D flammable fluids (T4 at 60 °C: -50 °C Ta 60 °C) Hazardous locations; Enclosure Type 4X

Canadian Standards Association (CSA)

N0 Non-incendive for Class I, Division 2, Groups A, B, C, and D non-flammable fluids (T4 at 60 °C: -50 °C Ta 60 °C), and Dust-ignition proof Class 2/III, Division 1, Groups E, F, and G (T5 at 60 °C) Hazardous locations; Enclosure Type 4X

B-2

Page 88
Image 88
Emerson Rosemount 8732 manual North American Certifications FM Approvals, Canadian Standards Association CSA