Rosemount 8732

Reference Manual

00809-0100-4665, Rev AA August 2010

Index

Parameter Name

Description

117

METER_VERIF_TEST_COND_IN

Incoming Test Condition of the Flowmeter

 

 

Verification Test

 

 

Note: This parameter needs to be configured

 

 

before the Meter Verification is started via the

 

 

PERFORM_METER_VERIFY parameter.

118

METER_VERIF_TEST_COND_OUT

Actual Test Condition of the Flowmeter

 

 

Verification Test.

119

METER_VERIF_CRITERIA

Test limits that the Flowmeter Verification Test

 

 

was ran against.

120

METER_VERIF_RESULT

Flowmeter Verification Test summary result.

121

COIL_RESIST_RESULT

Coil Resistance Test Result, part of the

 

 

Flowmeter Verification Test.

122

COIL_INDUCT_RESULT

Coil Inductance Test Result, part of the

 

 

Flowmeter Verification Test.

123

ELECT_RESIST_RESULT

Electrode Resistance Test Result, part of the

 

 

Flowmeter Verification Test.

124

INT_SIM_RESULT

Internal Simulator Test Result, part of the

 

 

Flowmeter Verification Test.

125

Reserved

Reserved.

126

COIL_INDUCT_VALUE

Coil Inductance value.

127

COIL_INDUCT_DEVIATION

Coil Inductance Deviation.

128

COIL_INDUCT_FINGERPRINT

Coil Inductance Fingerprint.

 

 

Note: These values should be made Read

 

 

Only in the DD. Only reset by the factory

 

 

parameter NV_RESET, not by the RESTART

 

 

w/ defaults.

129

COIL_RESIST_VALUE

Coil Resistance value

130

COIL_RESIST_FINGERPRINT

Coil Resistance Fingerprint

 

 

Note: These values should be made Read

 

 

Only in the DD. Only reset by the factory

 

 

parameter NV_RESET, not by the RESTART

 

 

w/ defaults.

131

ELECT_RESIST_VALUE

Electrode Resistance value

132

ELECT_RESIST_FINGERPRINT

Electrode Resistance Fingerprint

133

INT_SIM_DEVIATION

The internal flow simulator reading as a

 

 

percent deviation from the reference value.

134

INT_SIM_REF_VALUE

Internal Flow Simulator Reference Value

135

INT_SIM_VALUE

The internal flow simulator reading.

136

METER_VERIF_EP_LIM

Flowmeter Verification Limit – Empty Pipe

 

 

condition.

137

METER_VERIF_FLOWING_LIM

Flowmeter Verification Limit – Flowing

 

 

condition.

138

METER_VERIF_NO_FLOW_LIM

Flowmeter Verification Limit – No Flow

 

 

condition.

139

RECALL_FINGERPRINT_VALUES

Perform a recall of the previous fingerprint

 

 

values.

140

PERFORM_REFINGERPRINT_FLO

Perform the re-fingerprint command.

 

WTUBE

Note: The parameter

 

 

FINGERPRINT_SELECT needs to be

 

 

configured before the Refingerprint operation

 

 

is started.

141

PERFORM_METER_VERIFY

Perform the meter verification command.

 

 

Note: The parameter

 

 

METER_VERIF_TEST_SCOPE and

 

 

METER_VERIF_TEST_COND_IN needs to

 

 

be configured before the Refingerprint

 

 

operation is started.

G-4

Page 160
Image 160
Emerson Rosemount 8732 manual Meterveriftestcondout