MOUNTING AND WIRING INSTRUCTIONS

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and the mounting surface by using silicone or similar caulking.

1.Turn off power at circuit box to avoid possible electric shock.

2.Thread mounting screws (A) into mounting bar (B) (see fig. 1) approximately 1/4 inch.

3.Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).

4.To connect wires, take black fixture wire (group A from fig. 2 on page 11) and place evenly against black outlet box wire. Do not twist wires.

5.Fit wire connector (E from fig. 1) over wires and twist until there is a firm connection. If wire connector (E) easily comes off, reattach wire connector (E) and check again for a firm connection (see figure 1).

6.Repeat steps 4 and 5 with the white (group B from fig. 2) fixture wire and outlet box wires.

7.Partially thread green grounding screw (F) into side hole (G) on mounting bar (B) (see figure 1).

8.Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box (C) around green grounding screw (F) on mounting bar (B).

9.Tighten green grounding screw (F). Do not over tighten.

10.Tuck wires inside outlet box (C).

FIXTURE ASSEMBLY INSTRUCTIONS

1.Raise canopy (H) to ceiling allowing mounting screws (A) to protrude through key slots (I) in canopy (H) (see fig. 1).

2.Rotate canopy (H) clockwise until mounting screws (A) lock into narrow portion of key slots (I).

3.Install lamp(s). Do not exceed recommended wattage.

4.Raise glass shade (J) to canopy (H) allowing nipple (K) to protrude through opening.

5.Carefully support glass shade (J) while securing washer (L), hex nut (O), cap (M), and finial (N) to nipple (K).

6.Turn power back on at circuit box.

4

Image 4
Contents Guide d’utilisation Manual del Usuario Warranty Information Electrical Shock can Result in Serious InjuryLine art shown may not exactly match the fixture enclosed Mounting and Wiring Instructions Fixture Assembly InstructionsGarantie Limitée DE Cinq ANS FIL DE Mise Instructions DE Montage ET DE Raccordement Instructions D’ASSEMBLAGE DE Lappareil DéclairageGarantía Limitada DE Cinco Años Advertencia UNA Descarga Eléctrica Podría Causar LesionesFigura Instrucciones DE Montaje Y Cableado Instrucciones DE Montaje DEL ArtefactoMise EN Garde AdvertenciaCleaning and Care Commande DE PiècesOrdering Parts Nettoyage ET Entretien