Desa CD42M-A, CD36M, CD32M Troubleshooting, Observed Problem Possible Cause Remedy

Page 15

TROUBLESHOOTING

15

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot will not stay lit

1.

Defective thermocouple

1.

Check pilot flame. It must impinge on

 

 

 

 

thermocouple

 

 

 

2.

Clean or adjust pilot for maximum flame

 

 

 

 

impingement on thermocouple

 

 

 

3.

Ensure the connection between valve

 

 

 

 

and thermocouple are tight and secure

 

 

 

4.

Check thermocouple with millivolt

 

 

 

 

meter. Take reading at thermocouple ter-

 

 

 

 

minals of gas valve with remote control

 

 

 

 

off. It should read 18 millivolts mini-

 

 

 

 

mum. Replace faulty thermocouple if

 

 

 

 

reading is below specified minimum

 

 

 

 

 

Pilot lit but no flame on burner

1.

Remote or wires defective

1.

Check remote wires for proper connec-

 

 

 

 

tions. Place jumper wire across termi-

 

 

 

 

nals at remote control. If burner comes

 

 

 

 

on, replace remote. If okay, place jumper

 

 

 

 

wire across remote control at valve. If

 

 

 

 

burner comes on, wires are faulty or con-

 

 

 

 

nections are bad

 

2.

Thermopile not generating sufficient

2.

Check thermopile with millivolt meter.

 

 

milivoltage

 

Take reading at thermopile terminals of

 

 

 

 

gas valve with remote control off. It

 

 

 

 

should read 325 millivolts minimum.

 

 

 

 

Replace thermopile if reading is below

 

 

 

 

specified minimum

 

3.

Plugged burner orifice

3.

Check burner orifice for stoppage and

 

 

 

 

remove

Frequent pilot outage

1. Pilot flame may be too low or blowing

 

(high) causing safety pilot to “drop out”

1.Clean and/or adjust pilot flame for maximum flame impingement on thermocouple

For..com

111916-01A

Image 15
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Introduction Table of ContentsMantel Clearances PRE-INSTALLATION PreparationSelecting Location Clearances to CombustiblesFraming Vent Termination ClearancesMinimum Clearances for Vent Terminations Installation Venting Installation PrecautionsVenting Installation GAS Supply Testing Electrical Hookup and Remote Receiver DiagramGAS Line HOOK-UP Pilot AdjustmentRemoving Glass Panel Installing LOG SETModel CD42M-A Burner Flame Adjustment Decorative FacingFace Extension for Model CD32M only Lighting Instructions For Your Safety Read Before Lighting Operating Fireplace Operation GuidelinesConverting Fireplace from Natural GAS to PROPANE/LP GAS Converting PilotTo Turn OFF GAS To Appliance Converting Control Valve Installing New Parts for Gas Control Valve ConversionObserved Problem Possible Cause Remedy TroubleshootingModels CD32M CD36M-A Series Illustrated Parts BreakdownKEY Part Number CD32M CD36M-A Description QTY Parts ListModel CD42M-A Not a field replaceable part Wiring Diagram SpecificationsMillivolt Accessory and Replacement PartsNot a UPC