Desa CD32M, CD42M-A, CD36M installation manual Minimum Clearances for Vent Terminations

Page 5

PRE-INSTALLATION PREPARATION

5

PRE-INSTALLATION PREPARATION

Continued

D

E

V

B

L

C

H

N

N

Fixed

 

V

Closed

 

 

 

Openable

 

F V

Openable

B

Fixed

Closed

V

B

I

G

B

B

V J X

G

A

M

V

K X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5cm) minimum]

B= clearance to window or door that may be opened

[12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the center-line of the terminal [18 inches (45.7cm) minimum]

E= clearance to unventilated soffit [12 inches (30.5cm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (30.5cm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]

L= clearance above paved side-walk or a paved driveway located on public property [*84 inches (213.4cm) minimum]

M= clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ]

N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow

the current National Fuel Gas Code, ANSI Z223.1

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

A

 

A = 6" (15.2cm)

 

V

Outside Corner

V

B B = 6" (15.2cm)

Recessed Location

D

C

C

E

V

Balcony with No Side Wall

G

V

G = Combustible 24" (61cm) Noncombustible 18" (45.7cm)

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (96.5cm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)

Figure 5 - Minimum Clearances for Vent Terminations

For..com

111916-01A

Image 5
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Introduction Table of ContentsSelecting Location PRE-INSTALLATION PreparationClearances to Combustibles Mantel ClearancesFraming Vent Termination ClearancesMinimum Clearances for Vent Terminations Venting Installation InstallationVenting Installation Precautions GAS Supply Testing Electrical Hookup and Remote Receiver DiagramGAS Line HOOK-UP Pilot AdjustmentRemoving Glass Panel Installing LOG SETModel CD42M-A Face Extension for Model CD32M only Burner Flame AdjustmentDecorative Facing Operating Fireplace For Your Safety Read Before LightingOperation Guidelines Lighting InstructionsTo Turn OFF GAS To Appliance Converting Fireplace from Natural GAS to PROPANE/LP GASConverting Pilot Converting Control Valve Installing New Parts for Gas Control Valve ConversionObserved Problem Possible Cause Remedy TroubleshootingModels CD32M CD36M-A Series Illustrated Parts BreakdownKEY Part Number CD32M CD36M-A Description QTY Parts ListModel CD42M-A Not a field replaceable part Wiring Diagram SpecificationsMillivolt Accessory and Replacement PartsNot a UPC