Desa CD36M, CD42M-A, CD32M Electrical Hookup and Remote Receiver Diagram, GAS Supply Testing

Page 7

INSTALLATION

Venting Installation (Con.)

Electrical Gookup and Remote Reeiver Diagram

Gas Supply Testing

7

INSTALLATION

Continued

If an offset is necessary in the attic to avoid obstruction, it is important to support the vent pipe every 3 ft. to avoid excessive stress on the elbows and possible separation (see Figure 8, page 7).

Clearances must be maintained between the roof and the ter- mination. Refer to chart below.

Roof Pitch

Minimum Height Above Roof

 

 

Flat - 7/12

1 ft. (30.48 cm)

7/12 - 8/12

1 1/2 ft. (45.72 cm)

8/12 - 9/12

2 ft (60.96 cm)

9/12 - 10/12

2 1/2 ft (76.20 cm)

10/12 - 11/12

4 ft (121.92 cm)

11/12 - 14/12

5 ft (152.40 cm)

14/12 - 16/12

6 ft (182.88 cm)

16/12 - 18/12

7 ft (213.36 cm)

18/12 - 20/12

7 1/2 ft (228.60 cm)

20/12 - 21/12

8 ft (243.84 cm)

 

 

Outlet Box

Three-prong Plug

Figure 9 - Duplex Outlet

 

 

H

 

 

T

 

PI LOT

P

 

ON

 

TO

T

 

L

 

 

IP

 

 

F

H

 

FO

 

 

T

 

T

P

 

T

 

H

 

 

P

 

 

T

 

Convertible

H

 

T

 

 

P

 

 

T

 

Gas Valve

REMOTE

OFF

 

 

 

ON

Remote Control

Receiver

Figure 10 - Remote Control Receiver

Roof Flashing

Wall Strap

45° Elbows

Ceiling Firestop

Figure 8 - Vertical Termination with Offset and Wall Strap

ELECTRICAL HOOKUP AND REMOTE RECEIVER DIAGRAM

An outlet box with two receptacles (see Figure 9) has been supplied for your convenience and is located inside on the lower right side of the fireplace.

The remote control receiver is factory wired and connected to the convertible gas valve as shown in Figure 10.

GAS SUPPLY TESTING

NOTICE: This section is intended as a guide for qualified technicians installing gas to the appliance.

WARNING: Do not connect appliance before pres- sure testing gas piping. Damage to gas valve may result and an unsafe condition may be created.

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

The gas control valve is secured underneath the firebox. Two 1/8" ports are provided on the gas control valve for pressure test gauge connections (see Figure 11).

 

 

Pilot Adjustment

 

To Pilot Burner

 

 

 

 

ON/OFF

 

 

 

ILOT

 

Pilot Gas

Knob

 

 

 

 

Line Do

 

 

 

P

 

 

N

 

16AI

 

 

 

 

 

 

 

 

O

 

 

Not Kink

 

P

 

 

 

 

O

T

 

 

TH

 

 

 

 

7

 

 

I

 

 

 

L

 

 

 

 

 

 

 

L

I

 

To Main

 

 

FFO

O

H

TP

 

 

 

 

 

E

A

 

TPTH

Burner

Inlet

 

 

 

 

 

 

 

Flame Adjustment Knob

Pressure

 

 

 

Outlet Pressure

 

 

 

 

 

Figure 11 - Gas Control Valve

 

 

For..com

111916-01A

Image 7
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Introduction Table of ContentsMantel Clearances PRE-INSTALLATION PreparationSelecting Location Clearances to CombustiblesFraming Vent Termination ClearancesMinimum Clearances for Vent Terminations Venting Installation Precautions InstallationVenting Installation GAS Supply Testing Electrical Hookup and Remote Receiver DiagramGAS Line HOOK-UP Pilot AdjustmentRemoving Glass Panel Installing LOG SETModel CD42M-A Decorative Facing Burner Flame AdjustmentFace Extension for Model CD32M only Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Operation GuidelinesConverting Pilot Converting Fireplace from Natural GAS to PROPANE/LP GASTo Turn OFF GAS To Appliance Converting Control Valve Installing New Parts for Gas Control Valve ConversionObserved Problem Possible Cause Remedy TroubleshootingModels CD32M CD36M-A Series Illustrated Parts BreakdownKEY Part Number CD32M CD36M-A Description QTY Parts ListModel CD42M-A Not a field replaceable part Wiring Diagram SpecificationsMillivolt Accessory and Replacement PartsNot a UPC