Desa VDCFTN, CDCFTN, CDCFTP Optional Wall Mounted Thermostat GWMT1, Remote-Ready Models Only

Page 18

18

INSTALLATION

Optional Wall Mounted Thermostat - GWMT1 (Remote-Ready Models Only) Optional Wall Switch - GWMS2 (Remote-Ready Models Only)

INSTALLATION

Continued

OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

(Remote-Ready Models Only)

WARNING: Read and follow installation instruc- tions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Remove jumper wire from control valve (see Figure 26, page 17).

2.Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the "THTP" terminal on the control valve. See Figure 31.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air condi- tioning ducts.

4.Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

5.Feed the electrical wires through the rectangular slots on each side of the base (see Figure 32).

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

6.Connect one bare wire end to each terminal (“W” and “R”) of the thermostat base (see Figure 33).

Control Valve

To Wall Thermostat or Switch

To Wall Thermostat or Switch

Figure 31 - Connecting Wire Terminals

7.Install the base onto the wall with the provided screws.

8.Move the temperature adjustment back and forth to insure the bimetal is free from restrictions.

9.Replace the cover onto the base. (Upon installation, the ther- mostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation).

10.Set the temperature adjustment to the desired setting. This ther- mostat has been electronically calibrated at the factory. No ad- justment or leveling is necessary.

Feed wires through rectangular slots

Terminal “W”

W

 

Terminal “R”

R

Figure 32 - Back View of

Figure 33 - Thermostat Base

Thermostat Base

Terminals “W” and “R”

OPTIONAL WALL SWITCH - GWMS2 (Remote-Ready Models Only)

WARNING: Read and follow installation instruc- tions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

WARNING: Do not connect this switch to any electri- cal source! Electrical shock and/or fire hazard will occur.

1.Remove jumper wire from control valve (see Figure 26, page 17).

2.Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the "THTP" terminal on the control valve. See Figure 31.

3.Route the 25 ft. wire to a convenient location to mount your wall switch (no outside walls).

WARNING: Do not connect the switch to a power source. Electrical shock and/or fire hazard will occur.

IMPORTANT: The wire may be shortened but must not be lengthened.

4.Connect one bare wire end to each of the terminals of the pro- vided wall switch.

5.Install the wall switch and cover in the wall.

For..com

111244-01A

Image 18
Contents Thermostat Models OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Remote-Ready ModelsTable of Contents Safety InformationProduct Identification Vent-Free Compact Dual Flame FireplaceHood Assembly Optional Remote Control AccessoriesProduct Features Local CodesAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsInstallation Items Check GAS TypeFireplace Clearances BUILT-IN Fireplace Installation Actual Framing Height 26 7 Front Width 26 3 Depth 14 1 15 1Optional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Optional Blower Accessory GA3450TA Removing Upper LouverInstalling Blower Accessory Wiring Diagram For Blower Accessory Standard InstallationFor Built-In Installation Extension CordConnecting to GAS Supply NaturalConnecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing Gas Supply Piping system Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Optional Wireless HAND-HELD Remote Control Accessories Installing ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1 Remote-Ready Models OnlyInstalling LOG SET and Screen Operating FireplaceLighting Instructions Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Operating BlowerREMOTE-READY Models For Your Safety Read Before Lighting Propane/LPGasPilotON/OFF Series Model Cghrcb Manual ModeAuto Thermostatic Mode Optional HAND-HELD Remote OperationOptional GWMS2 Wall Mounted Switch Safety FeaturesOptional GWMT1 Wall Mounted Thermostat Inspecting Burners Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Pilot Flame PatternCleaning and Maintenance Wiring Diagram LOG SETCabinet Troubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Gas leak. See Warning statement Technical Service SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown FireboxParts List Description QTYThermostat Models FDCFTP, FDCFTN, Vdcftp Thermostat Models Parts Available not ShownVdcfrp REMOTE-READY Models FDCFRN, FDCFRP, VdcfrnREMOTE-READY Models KEY Fdcfrp Fdcfrn Vdcfrp Vdcfrn Description QTYAccessories WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCK/CCKWALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Remote Control KIT Ghrcb and CghrcbFor . .com Owners Registration Form Postage Required 111244-01A Not a UPC