Desa VDCFRN, CDCFTN, CDCFTP Specifications, Service Hints, Technical Service, Replacement Parts

Page 29

SPECIFICATIONS

SERVICE HINTS TECHNICAL SERVICE REPLACEMENT PARTS

29

SPECIFICATIONS

 

Thermostat Models:

Thermostat Models:

Remote-Ready Models:

Remote-Ready Models:

 

CDCFTP, VDCFTP,

CDCFTN, VDCFTN,

VDCFRP, FDCFRP

VDCFRN, FDCFRN

 

FDCFTP

FDCFTN

 

 

Btu/Hr

17/26,000

17/26,000

17/26,000

17/26,000

Type Gas

Propane/LP Gas Only

Natural Gas Only

Propane/LP Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

8" W.C.

3.5" W.C.

8" W.C.

3.5" W.C.

Inlet Gas Pressure

 

 

 

 

(in. of water)

 

 

 

 

Maximum

14"

10.5"

14"

10.5"

Minimum*

11"

5"

11"

5"

Dimensions, inches (HxWxD)

 

 

 

Fireplace

25 7/8 x 26 13/16 x 15 5/16

25 7/8 x 26 13/16 x 15 5/16

25 7/8 x 26 13/16 x 15 5/16

25 7/8 x 26 13/16 x 15 5/16

(including hood

 

 

 

 

and screws)

 

 

 

 

* For purpose of input adjustment

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical services web site at www.desatech.com.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your fireplace

the replacement part number

For morevisit www..com

111244-01A

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualThermostat Models Remote-Ready ModelsSafety Information Table of ContentsVent-Free Compact Dual Flame Fireplace Product IdentificationProduct Features Optional Remote Control AccessoriesHood Assembly Local CodesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationFireplace Clearances Installation ItemsCheck GAS Type Actual Framing Height 26 7 Front Width 26 3 Depth 14 1 15 1 BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationRemoving Upper Louver Installing Optional Blower Accessory GA3450TAWiring Diagram For Blower Accessory Standard Installation Installing Blower AccessoryExtension Cord For Built-In InstallationNatural Connecting to GAS SupplyInstallation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing Gas Supply Piping systemPressure Testing Fireplace Gas Connections Installing 9-Volt Battery in Hand-Held Remote Control Unit Optional Wireless HAND-HELD Remote Control AccessoriesInstalling Receiver Remote-Ready Models Only Optional Wall Mounted Thermostat GWMT1Lighting Instructions Installing LOG SET and ScreenOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Operating BlowerPropane/LPGasPilot REMOTE-READY Models For Your Safety Read Before LightingAuto Thermostatic Mode Manual ModeON/OFF Series Model Cghrcb Optional HAND-HELD Remote OperationOptional GWMT1 Wall Mounted Thermostat Optional GWMS2 Wall Mounted SwitchSafety Features Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceInspecting Burners Pilot Flame PatternCabinet Cleaning and Maintenance Wiring DiagramLOG SET Observed Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Gas leak. See Warning statement Service Hints SpecificationsTechnical Service Replacement PartsFirebox Illustrated Parts BreakdownDescription QTY Parts ListThermostat Models FDCFTP, FDCFTN, Vdcftp Parts Available not Shown Thermostat ModelsREMOTE-READY Models FDCFRN, FDCFRP, Vdcfrn VdcfrpKEY Fdcfrp Fdcfrn Vdcfrp Vdcfrn Description QTY REMOTE-READY ModelsAccessories WALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT GCK/CCKWALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT Ghrcb and CghrcbFor . .com Owners Registration Form Postage Required 111244-01A Not a UPC