Char-Broil 463666508 manual LP Liquefied Petroleum Gas, LP Cylinder Filling

Page 4
Retainer Strap
LP Cylinder Valve
Safety Cap

USE AND CARE

DANGER

NEVER store a spare LP cylinder under or near the appliance or in an enclosed area.

Never fill a cylinder beyond 80% full.

An over filled or improperly stored cylinder is a hazard due to possible gas release from the safety relief valve. This could cause an intense fire with risk of property damage, serious injury or death.

If you see, smell or hear gas escaping, immediately get away from the LP cylinder/appliance and call your fire department.

LP Cylinder Removal, Transport and Storage

Turn OFF all control knobs and LP cylinder valve. Turn coupling nut counterclockwise by hand only - do not use tools to disconnect. Loosen cylinder screw beneath bottom shelf, then lift LP cylinder up and out of cart. Install safety cap onto LP cylinder valve. Always use cap and strap supplied with valve. Other types of caps or plugs may result in leakage of propane.

Failure to use safety cap as directed may result in serious personal injury and/or property damage.

• A disconnected LP cylinder in

storage or being transported must have a safety cap installed (as shown). Do not store an LP cylinder in enclosed spaces such as a carport, garage, porch, covered

patio or other building. Never leave an LP cylinder inside a vehicle which may become overheated by the sun.

• Do not store an LP cylinder in an area where children play.

LP Cylinder

The LP cylinder used with your grill must meet the following requirements:

Use LP cylinders only with these required measurements: 12" (30.5cm) (diameter) x 18" (45.7 cm) (tall) with 20 lb. (9 kg.) capacity maximum.

LP cylinders must be constructed and marked in accordance with specifications for LP cylinders of the U.S. Department of Transportation (DOT) or for Canada, CAN/CSA-B339, cylinders, spheres and tubes for transportation of dangerous goods. Transport Canada (TC). See LP cylinder collar for marking.

LP cylinder valve must have:

Type 1 outlet compatible with regulator or grill.

Safety relief valve.

• UL listed Overfill Protection

OPD Hand Wheel

Device (OPD). This OPD safety

feature is identified by a unique triangular hand wheel. Use

only LP cylinders equipped with this type of valve.

LP cylinder must be arranged for vapor withdrawal and include collar to protect LP cylinder valve. Always keep LP cylinders in upright position during use, transit or storage.

LP cylinder in upright position for

vapor withdrawal

LP (Liquefied Petroleum Gas)

LP gas is nontoxic, odorless and colorless when produced. For Your Safety, LP gas has been given an odor (similar to rotten cabbage) so that it can be smelled.

LP gas is highly flammable and may ignite unexpectedly when mixed with air.

LP Cylinder Filling

Use only licensed and experienced dealers.

LP dealer must purge new cylinder before filling.

Dealer should NEVER fill LP cylinder more than 80% of LP cylinder volume. Volume of propane in cylinder will vary by temperature.

A frosty regulator indicates gas overfill. Immediately close LP cylinder valve and call local LP gas dealer for assistance.

Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.

To remove gas from LP cylinder, contact an LP dealer or call a local fire department for assistance. Check the telephone directory under “Gas Companies” for nearest certified LP dealers.

4 • 463666508

Image 4
Contents Model 463666508 Product Guide Call Grill Service Center for Help and Parts Installation Safety PrecautionsSafety Symbols For residential use only. Do not use for commercialTable of Contents LP Liquefied Petroleum Gas LP Cylinder FillingUL listed Overfill Protection Only LP cylinders equipped with this type of valveConnecting Regulator to the LP Cylinder For your safetyUseDo not household cleaning agents. Damage to gas LP Cylinder ExchangeConnection, do not use this regulator Leak Testing Valves, Hose and RegulatorTurn all grill control knobs to OFF For Safe Use of Your Grill and to Avoid Serious Injury General Grill Cleaning Ignitor LightingBurner Flame Check Turning Grill OffStoring Your Grill Cleaning the Burner AssemblyTurn gas off at control knobs and LP cylinder Food Safety How To Tell If Meat Is Grilled ThoroughlyDescription Key KeyDescription Parts Diagram Model No Assembly Model No Valve #10-24 wing nuts Flange NutCenter flat portion Hinge on bottom Should curve downward when properly installed Cooking grate 80012776 Vaporiser bar 80012775 Grease clip 80000271 Grease cup 80000270 LP Cylinder Limited Warranty Troubleshooting Emergencies Possible Cause Prevention/SolutionPiezo PUSH-BUTTON and Rotary Please register your grill online at This Intentionally blank This Intentionally blank This Intentionally blank Grilling Safety Checklist Thank You for Your Purchase