Vulcan-Hart VCB25M ML-44963Z, VCB47M ML-44965Z General, Installation, Unpacking, Location

Page 3

INSTALLATION, OPERATION AND CARE OF

MODEL VCB SERIES CHARBROILERS

PLEASE KEEP THIS MANUAL FOR FUTURE USE

GENERAL

Vulcan-Hart Charbroilers are produced with quality workmanship and material. Proper installation, usage and maintenance of your charbroiler will result in many years of satisfactory performance.

It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions provided.

INSTALLATION

Before installing, verify that the type of gas supply (natural or propane) agrees with the specifications on the rating plate located on the right inside panel. If the supply and equipment requirements do not agree, do not proceed with the installation. Contact your dealer or Vulcan-Hart Company immediately.

UNPACKING

This charbroiler was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage. If the charbroiler is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

Carefully unpack charbroiler and place in a work-accessible area as near to its final installed position as possible.

LOCATION

The equipment area must be kept free and clear of combustible substances.

This charbroiler is design certified for installation on a non-combustible counter with 4" (10 cm) legs, or on a combustible floor with a 24" (61 cm) high cabinet or stand with the following minimum clearances to adjacent wall construction:

 

Minimum Clearance

Combustible

Non-Combustible

 

From:

Construction

Construction

 

 

 

 

 

Back

 

Above Grid Level

12" (30 cm)

3" (8 cm)

 

Below Grid Level

3" (8 cm)

3" (8 cm)

 

 

 

 

 

 

 

Sides

 

Above Grid Level

9" (23 cm)

0"

 

Below Grid Level

3" (8 cm)

0"

 

 

 

 

 

 

 

– 3 –

Image 3
Contents Installation For Your Safety Important for Your SafetyLocation InstallationGeneral UnpackingInstallation Codes and Standards CanadaLeveling Testing the GAS Supply System GAS ConnectionsFlue Connections Operation Cleaning Drip PANDaily Lubrication MaintenanceRecommended Service Frequency Service and Parts Information