Genesis Advanced Technologies Gas Grill manual Install manifold bracket, Install frame connector

Page 14

Install manifold bracket

You will need: manifold bracket.

Hook the bracket(2) onto the manifold in the center. Place your hand underneath the bracket. Lift the manifold, bracket and cooking box slightly, then hook the tab of the bracket onto the frame brace(1).

(1)(2)

Install frame connector

You will need: frame connector, two 1 3/4 inch bolts, two nylon washers and a 7/16 inch or adjustable wrench.

Add nylon washer to the bolt, insert bolt through the hole in the bottom center of the wheel frame and into the end of the frame connector(1). Insert the other bolt with a washer on it through the leg frame and into the other end of the frame connector. Hold the frame connector square and tighten the bolts with the wrench.

(1)

Install Gas Supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must confirm to the latest edition of ANSI Z223.1. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifications.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected

The quick disconnect fitting can be installed horizontally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to

rigid, permanent construction.

￿WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

B-4

Image 14
Contents Gas Grill Liquid Propane GAS Units only Palatine, IL Customer Service CenterSouth Hicks Road Contents Storage Gas Supply TestingFor Installation in Canada OperatingGenesis Silver-A NG Page Page Page Page Assemble wheel frame Assemble frameAdd Wrap-around Frame Panel Continue frame assemblyInstall tubing plugs Add cooking box assembly Install Gas Supply General Specifications for Piping Install manifold bracketInstall frame connector Test Connections Install igniterGas Line Piping Check that all burner valves are off Connect flexible hose to manifoldPage Install the slide out bottom tray Install Lid Installing Features Install the left end trim pieceInstall the bottom shelf Installing the warming rackLighting To ExtinguishBarbecue’s burners, or not waiting 5 min Manual LightingFailure to open lid while igniting Storage CleaningCooking Cast Iron Cooking Grates Care Instructions Seasoning Cast Iron Grates a Solid vegetableLeaks. Be sure there are no sparks or open Annual MaintenanceDo not use an open flame to check for gas Main Burner Flame Pattern General MaintenanceMain Burner Cleaning Procedure Weber Spider Stopper GuardsReplacing Main Burners Positioned properly over the valve orifices2Crossover Ignition System Operations Orange flame, in conjunction with Flame is low when burner is onBurners burn with a yellow or Smell of gas