Outdoor Gourmet CG3023E Leak Testing the REGULATOR, VALVES, HOSES, and Connections

Page 27

.C.C.1 Type 1 Connector

The regulator must enter the cylinder valve in a straight line.

Center this nipple of the regulator into the cylinder valve.

! WARNING

Always keep the gas cylinder in the upright position at all times

!WARNING

1.Do not connect this grill to any unregulated sources of propane.

2.Before each use, check the gas hose for excessive abrasion or wear, or cuts. Replace a hose assembly showing those signs with the hose assembly specified in the parts list before using the grill. Inspect the hose assembly by opening the cabinet door underneath the side burner and following the regulator hose up to its connection to the gas manifold assembly.

3.Always perform the Leak Test listed below before using your grill for the first time, if the cylinder has been changed, any gas components have been changed, the regulator flow-limiting device has been activated, or after a long period of non-use.

4.Do not attempt to connect this grill to the LP system of a motor home or trailer.

LEAK TESTING THE REGULATOR, VALVES, HOSES, AND CONNECTIONS

1.Ensure the LP cylinder valve and all burners are “Off”.

2.Ensure the LP cylinder is connected to the regulator.

3.If the information in1 & 2 is not followed exactly, a fire causing death or serious injury may occur.

4.Mix up a solution of 50% water and 50% liquid dish soap. Do not use any household cleaner solution.

5.Open the LP tank valve by turning the hand wheel counterclockwise one turn. If you hear a rushing sound, turn the gas off immediately. In that case, there could be a leak at the connection. Reconnect the cylinder to the regulator.

6.Spray or brush on the solution covering the following areas: cylinder welds, regulator and cylinder connection, gas hose connections to the regulator, all gas hoses, all gas hose connections to the burners including the main and side burners.

7.Growing bubbles on any of the parts and connections listed above indicate a gas leak. Immediately shut off the LP tank valve by turning the valve clockwise. Retighten the connections or order replacement parts as needed. Continue to test as necessary until no leaks are detected.

8.Close the LP tank valve by turning the hand wheel clockwise.

!WARNING

1.DO NOT USE THE GRILL if you cannot stop the leaks. Be sure the LP cylinder valve is closed. If the LP cylinder is still leaking, contact your LP dealer or local fire department.

2.Do not use any match or open flame, or smoke, during leak testing.

3.Do not light a burner during leakGrilltesting. Placement

4.The replacement hose assembly must be the one identified.

27

Image 27
Contents Assembly Instructions For Your Safety Safety Precautions Table of Contents Tools Required Parts List Page Hardware Assembly Instructions Assembly Instructions Do not Install Cylinder AT this Time Assembly Instructions Assembly Instructions Assembly Instructions Assembly Instructions Attach 2-BOLTS M6x12 B into the body of firebox Assembly Instructions Assembly Instructions Assembly Instructions Assembly Instructions Assembly Instructions Put 6-cooking grid8 into the grill body. As showen below Final Assembly Operation GAS GrillLP Cylinder Leak Test LP Cylinder Filling and ExchangeTo Connect the Cylinder to the Regulator and Hose Transportation and StorageLeak Testing the REGULATOR, VALVES, HOSES, and Connections Lighting For Your SafetyLighting the Main Burners Using Electronic Ignition Lighting the Side Burner with Electronic IgnitionLighting the Side Burner with the Match Lighting Stick Turning OFF Your Grill Cleaning Your GrillAlways Cleaning the BurnersElectronic Ignition Maintenance Burner FlamesDirect VS. Indirect Cooking Side BurnerGrilling Tips and Tricks Sudden Drop in GAS Pressure or Flames Blow OUT Food SafetyBurner will not Light Irregular Flame or Yellow FlameFire Behind Control Panel Excessive FLARE-UPSCharcoal Section and Smoker Adding Charcoal/Wood During Cooking AFTER-USE Safety Frequently Asked Questions