16 | OPERATING INSTRUCTIONS |
|
|
LIGHTING THE SIDE BURNER
DANGER
Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive
WARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber® authorized replacement hose. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
1)Open the side burner lid.
2)Check that the side burner valve is turned off (Push control knob in and turn clockwise to ensure that it is in the “OFF” position), turn all burners not being used to the “OFF” position (push in and turn clockwise).
WARNING: The burner control knobs must be in the OFF position before turning on the liquid propane cylinder valve. If they are not in the OFF position, when you turn on the LP cylinder valve, the “excess gas flow control” feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP tank valve and burner control knobs. Start over.
| 1 |
|
| 5 |
|
| 2 | 4 |
2 | 3 |
|
3)Turn the gas supply valve on.
4)Push down and turn the side burner control valve to “HI”.
5)Press the igniter button several times so it clicks each time.
DANGER
When the “excess gas flow control” feature is activated, a small amount of gas is still flowing to the burners. After turning OFF the cylinder and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the barbecue. Failure to do so may result in an explosive
CAUTION: Side burner flame may be difficult to see on a bright sunny day.
WARNING: If the side burner does not light in five (5) seconds:
a)Turn off the side burner control valve, main burners and gas supply at source.
b)Wait 5 minutes to let the gas clear before you try again, or try lighting with a match (see “Manually Lighting the Side Burner”).
MANUALLY LIGHTING THE SIDE BURNER
DANGER
Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive
1)Open the side burner lid.
2)Check that the side burner valve is turned off (Push control knob in and turn clockwise to ensure that it is in the “OFF” position), turn all burners not being used to the “OFF” position (push in and turn clockwise).
WARNING: The burner control knobs must be in the OFF position before turning on the liquid propane cylinder valve. If they are not in the OFF position, when you turn on the LP cylinder valve, the “excess gas flow control” feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP tank valve and burner control knobs. Start over.
| 1 |
| 4 |
| 5 |
| 6 |
2 | 3 |
WWW.WEBER.COM®