Napoleon Grills LD485RB manual Maintenance / Cleaning Instructions

Page 8

8

Maintenance / Cleaning Instructions

We recommend this gas grill be thoroughly inspected and serviced annually by a qualified service person.

Warning! Always wear protective gloves and safety glasses when cleaning your grill.

Warning! To avoid the possibility of burns, maintenance should be done only when the grill is cool. Avoid unprotected contact with hot surfaces. Ensure all burners are turned off. Clean grill in an area where cleaning solutions will not harm decks, lawns, or patios. Do not use oven cleaner to clean any part of this gas grill. Do not use a self-cleaning oven to clean cooking grids or any other parts of the gas grill. Barbecue sauce and salt can be corrosive and will cause rapid deterioration of the gas grill components unless cleaned regularly.

Note: Stainless steel tends to oxidize or stain in the presence of chlorides and sulfides, particularly in coastal areas and other harsh environments, such as the warm, highly humid atmosphere around pools and hot tubs. These stains could be perceived as rust, but can be easily removed or prevented. To provide stain prevention and removal, wash all stainless steel surfaces every 3-4 weeks or as often as required with fresh water and/or stainless steel cleaner.

WARNING! Turn off the gas at the source and disconnect the unit before servicing. To avoid the possibility of burns, maintenance should be done only when the grill is cool. A leak test must be performed annually and whenever any component of the gas train is replaced or gas smell is present.

Combustion Air Adjustment: (This must be done by a qualified gas installer.) The air shutter is factory set and should not need adjusting under normal conditions. Under extreme field conditions, adjustments might be required. When the air shutter is adjusted correctly the flames will be dark blue, tipped with light blue and occasionally yellow.

With too little air flow to the burner, the flames are lazy yellow and can produce soot.

With too much air flow, the flames lift erratically and can cause difficulties when lighting. Adjusting the air shutter:

1.Remove cooking grids and sear plates and leave lid open.

2.Loosen air-shutter lock screw located at the mouth of the burner and open or close air shutter as required. The normal opening settings are:

Main Tube Burner

Propane 5/32” (4mm)

 

Natural 5/32” (4mm)

*Infra-Red burners have no air adjustment.

3.Light the burners and set to high. Visually inspect burner flames. When the shutters are set correctly, turn burners off, tighten locking screws, and replace removed parts. Ensure that the insect screens are installed.

Light Blue

Burner

Yellow Tipping

Dark Blue

Burner Port

Approximately 1/2” (13mm)

www.napoleongrills.com

Image 8
Contents LD485RB Napoleon Gas Grill President’s Limited Warranty Safe Operating Practices Propane Cylinder Installation Cylinder Specification/Gas Hook UpPropane Cylinder Specifications Leak Testing Instructions Natural Gas Hook-UpLighting Instructions Operating The Grill Maintenance / Cleaning Instructions Page Troubleshooting Problem Possible Causes Solution Record information here for easy reference Ordering Replacement PartsWarranty Information Tools Required for Assembly tools not included Getting StartedMagnet Installation Caster/Bracket InstallationPropane Only Propane Tank Ring InstallationLeft and Right Cart Panel Installation Rear Cart Panel Installation Tank Inhibitor Bracket / Propane Tank Mount Installation Front Cabinet Support Installation Heat Shield InstallationTwo people are required for this step Correct Assembly Incorrect AssemblyGrill Head Installation Rotisserie Mount Installation Side Shelf Assembly Side Shelf Installation Door Assembly Cabinet Door Installation BushingSear Plate Installation Grids and Warming Rack InstallationGrease Tray and Holder Installation Drip Pan InstallationRotisserie Kit Assembly Instruction Propane Only Proper Hose Connection Propane Only Improper Hose ConnectionNatural Gas Only Proper Hose Connection Natural Gas Only Improper Hose Connection Leak Testing Instructions Parts List DescriptionPropane units only Natural gas units only x standard Page Accessories & Parts Order Form