Napoleon Grills BGNV42P, BGNV42N manual Adjustments, Maintenance, Pilot Burner Adjustment

Page 13

13

MAINTENANCE

Turn off the gas and electrical power before servicing the fireplace.

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of com- bustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacu- uming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly.

4.Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and reaches to- ward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer / dis- tributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.

FIGURE 29

OL

 

N

O

 

F

HI

O

F

 

 

P

 

 

TOLI

TOLIP

PILOT SCREW

FIGURE 28

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A

QUALIFIED GAS INSTALLER!

FIGURE 30

VENTURI ADJUSTMENTFIGURE 30

 

MODEL BGNV42

 

 

NG

1/8"

LP

5/16"

 

 

Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; al- low 15 to 30 minutes for the final flame colour to be estab- lished.

To access the air shutter, remove the two screws that se- cure the cover to the air housing, taking care not to dam- age the gasket.

VENTURI

COVER

FIGURE 31 (not exactly as shown)

W415-0377 / 03.04.03

Image 13
Contents Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting GAS Installation Framing InstallationMantle Clearances Nailing TAB InstallationDoor Installation Louvre Bracket InstallationL42 Louvre Installation GDL42 Louvre Installation Logo PlacementCharcoal Embers LOG PlacementVermiculite Charcoal LumpsOptional Blower Installation Thermostatic Sensor Control Optional FAN InstallationOperating Instructions Operation / MaintenanceMaintenance AdjustmentsPilot Burner Adjustment Venturi AdjustmentfigureReplacement Parts ReplacementsAccessories Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT