Napoleon Grills BGNV42N, BGNV42P manual Optional Blower Installation

Page 10

10

OPTIONAL BLOWER INSTALLATION

INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accord- ance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

red

black

white

Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the secur- ing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.

T H E R M O D I S C

RECEPTACLE /

JUNCTIONBOX

GROUND

SCREW

FIGURE 20

The three slots allow ease of adjustment of the blower. For a quiet running blower, do not allow the assembly to sit on the firebox base.

FIGURE 21

ADJUSTMENT SLOTS

FIGURE 24

Attach the connectors from the black and red wires to the blower.

Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.

Slide the vibration reducing pad (A) into the clip and onto the threaded stud (B) at the other end, piercing a hole into the pad. The blower must be able to be positioned entirely onto the pad.

Tilt the blower onto its side. Slide it past the controls and into the clip (C). Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fireplace base or the firebox.

B

C

A

FIGURE 22

FIGURE 23

FIGURE 25

The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making con- tact with moving or hot objects.

Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes after lighting the fireplace and will run for approximately 30-45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat.

Drywall dust will penetrate into the blower bear- ings causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not cov- ered by the warranty policy.

W415-0377 / 03.04.03

Image 10
Contents Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Installation GAS Installation FramingNailing TAB Installation Mantle ClearancesL42 Louvre Installation GDL42 Louvre Installation Louvre Bracket InstallationDoor Installation Logo PlacementVermiculite LOG PlacementCharcoal Embers Charcoal LumpsOptional Blower Installation Optional FAN Installation Thermostatic Sensor ControlOperation / Maintenance Operating InstructionsPilot Burner Adjustment AdjustmentsMaintenance Venturi AdjustmentfigureReplacement Parts ReplacementsAccessories Trouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT