SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

 

 

 

Pilot goes out Gas piping is undersized. while standing;

Main burner is in 'OFF' position.

Flames

are con-

Unit is over-fired or under-

sistently too large

fired.

 

 

or too

small.

 

 

 

Carboning occurs.

 

B

A

 

 

OL

 

 

 

 

 

N

O

 

 

 

F

 

 

HI

O

F

 

 

 

 

P

 

 

 

 

TOLI

 

P

 

 

 

 

TOLI

 

 

 

- turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure.

-check if supply piping size is to code. Correct all undersized piping.

-check pressure readings:

Inlet pressure can be checked by turning screw (A) counter-clock- wise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7" (minimum 4.5") water column for natural gas or 13" (11" minimum) water column for propane. Check that main burner is operating on "HI".

Outlet pressure can be checked the same as above using screw

(B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI".

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution.

Carbon is being

deposited on glass, logs or com- bustion chamber surfaces.

Air shutter has become

-

ensure air shutter opening is free of lint or other obstructions.

blocked

 

 

 

 

 

Flame is impinging on the

-

check that the logs are correctly positioned.

logs or combustion cham-

-

open air shutter to increase the primary air.

ber.

-

check the input rate: check the manifold pressure and orifice size

 

as specified by the rating plate values.

 

- check to ensure proper venting action

White / grey film Sulphur from fuel is being

forms.deposited on glass, logs or combustion chamber sur- faces.

-clean the glass with a recommended gas fireplace glass cleaner.

DO NOT CLEAN GLASS WHEN HOT.

If deposits are not cleaned off regularly, the glass may become permanently marked.

Exhaust

fumes

 

Fireplace is spilling.

- check for chimney blockage

smelled in

room,

 

 

- check that chimney is installed to building code.

headaches.

 

 

- room is in negative pressure; increase fresh air supply.

 

 

 

 

Main burner flame

Not enough combustion air

- room is in negative pressure; increase fresh air supply

is a blue,

lazy,

 

 

 

transparent flame.

 

 

 

 

 

 

 

 

Remote

wall

 

Wall switch is mounted up-

- reverse.

switch is in "OFF"

 

side down

 

position;

main

 

Remote wall switch is - replace.

burner comes on

 

grounding.

 

when gas knob is

 

 

 

 

Remote wall switch wire is

- check for ground (short); repair ground or replace wire.

turned to "ON" po-

 

sition.

 

 

grounding.

 

 

 

Faulty valve.

- replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

W415-0377 / 03.04.03

Image 16
Contents Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Installation GAS Installation FramingNailing TAB Installation Mantle ClearancesLouvre Bracket Installation Door InstallationL42 Louvre Installation GDL42 Louvre Installation Logo PlacementLOG Placement Charcoal EmbersVermiculite Charcoal LumpsOptional Blower Installation Optional FAN Installation Thermostatic Sensor ControlOperation / Maintenance Operating InstructionsAdjustments MaintenancePilot Burner Adjustment Venturi AdjustmentfigureReplacement Parts ReplacementsAccessories Trouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT