Continental CBI 360-P, CBI 360-N manual Operation / Maintenance, Logo Placement

Page 8

8

LOGO PLACEMENT

13/8"

LOGO

11/8"

Remove the backing of the logo supplied and place on the glass viewing area, as indicated.

FIGURE9

OPERATION / MAINTENANCE

SPILL SWITCH

This is a thermally activated switch, attached to the back of the unit and extending up into the dilution draft hood, which senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected vent.

It acts as a safety shut-off to prevent a build up of carbon monoxide or an explosion of unburnt gases during start up. If the flue is blocked or has no "draw", the spill switch will automatically shut off the supply of gas within about 5- 10 minutes.

TAMPERING WITH THE SWITCH CAN RESULT IN CAR- BON MONOXIDE (CO) POISONING AND POSSIBLE DEATH.

FIGURE10

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room.

VENTING ACTION CHECK

A CHECK FOR CORRECT VENTING ACTION MUST BE MADE BEFORE THE INSTALLED INSERT IS LEFT WITH THE CUSTOMER.

Test after installing the unit into a vented non-combustible fireplace in the following manner:

1.Close all doors and windows in the room; start exhaust fans in the home; turn fireplace blower off.

2.Set controls to "high" and light the unit.

3.Wait 5 minutes. Light a match and hold it to the spill tube opening.

4.Venting action is satisfactory if smoke is drawn into the spill tube. Venting action is unsatisfactory if the flame and smoke are not drawn into the tube.

5.If venting action is unsatisfactory, turn the unit off, wait 10 minutes and try again. If the smoke or flame is still not drawn into the spill tube, turn the unit off and check for vent blockage or restriction. If necessary, consult with a quali- fied air quality specialist.

After extended periods of non-operation such as follow- ing a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

W415-0120 / E / 01.11.05

Image 8
Contents GAS Inserts Table of Contents Conditions and Limitations Care of Glass and Plated General InstructionsGeneral Information Installation Wire Size MAX. Length Fibre Firebrick Panels LOG Placement FinishingOperation / Maintenance Logo PlacementMaintenance For Your Safety Read Before LightingAdjustments Pilot Burner AdjustmentVenturi Adjustment Blower SystemReplacements Replacement PartsW415-0120 / E Trouble Shooting Guide Symptom Problem Test SolutionPage Fireplace Service History W415-0120 / E

CBI 360-N, CBI 360-P specifications

The Continental CBI 360-N and CBI 360-P represent cutting-edge advancements in the realm of continental industrial solutions, designed specifically to meet the diverse needs of modern industries. These models stand out due to their innovative technologies, robust performance, and versatility, making them essential tools for various applications.

One of the defining features of the CBI 360-N and CBI 360-P is their exceptional durability. Built with high-quality materials, these models are engineered to withstand tough industrial environments, ensuring longevity and consistent performance even under extreme conditions. The robust construction not only enhances their lifespan but also reduces maintenance costs, offering a cost-effective solution for users.

Another significant aspect is the advanced monitoring and diagnostic technologies integrated into these models. They come equipped with smart sensors that provide real-time data on operating conditions, allowing for proactive maintenance and troubleshooting. This feature not only optimizes performance but also enhances safety by minimizing the risk of unexpected breakdowns.

The CBI 360-N and CBI 360-P also boast energy-efficient designs. With a focus on reducing energy consumption, these models are equipped with high-performance motors and intelligent control systems that optimize power usage. This not only contributes to lower operational costs but also aligns with global sustainability goals, making them an environmentally friendly choice.

Versatility is another hallmark of the CBI 360 series. The CBI 360-N is particularly suited for standard applications, while the CBI 360-P offers enhanced power capabilities for more demanding tasks. This flexibility allows operators to select the appropriate model based on their specific requirements, making these machines suitable for a wide range of industrial sectors, including manufacturing, logistics, and more.

Furthermore, user-friendly interfaces and intuitive controls are central to the design of the CBI 360-N and CBI 360-P. Operators can easily configure settings and monitor performance through streamlined control panels, enhancing productivity and reducing the learning curve for new users.

In conclusion, the Continental CBI 360-N and CBI 360-P stand at the forefront of industrial innovation, offering a blend of durability, efficiency, and versatility. Their advanced technologies and practical features make them invaluable assets for businesses looking to improve operational efficiency and reliability in an ever-evolving industrial landscape. With these models, Continental continues to lead the way in providing high-quality, dependable industrial solutions.