OPERATING FIREPLACE

To Turn Off Gas To Appliance

Optional Remote Operation

Operating Optional Blower Accessory

INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

OPERATING FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

3.Open lower louver panel.

4.Remove front hearth brick and control access panel.

5.Turn equipment shutoff valve clockwise to OFF. Do not force.

6.Close lower louver panel.

Pilot Burner

Sensing Rod

 

Ignitor

 

Figure 43 - Pilot

 

OPTIONAL REMOTE

OPERATION

 

Note: The WRC receiver and hand-held remote control kit

must be purchased separately (see Accessories, page 34). Follow

installation instructions on page 22.

 

1.Turn equipment shutoff valve to ON position. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

2.Press the ON/OFF button to turn the burner on and off.

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the right just inside the louver panel.

The BK manual blowerand the BKTthermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time.The fireplace may run forseveral minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Peri- odically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.

INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame. Altera- tions may have occurred during shipping and handling. The pilot is located on the left hand side of the burner.

The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem.

If your pilot assembly does not meet these requirements:

Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 42, page 23). Do not remove the adjustment screw.

see Troubleshooting, page 26

Pilot Burner

Sensing Rod

 

 

Ignitor/Sensor

Figure 44 - Correct Pilot Flame Pattern

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on instal- lation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after instal- lation to ensure proper installation and performance.

Figure 45 shows a typical flame pattern. If burner flame pattern differs from that described:

turn fireplace off (see To Turn Off Gas to Appliance)

see Troubleshooting, page 26

Figure 45 - Typical Flame Pattern

www.desatech.com

116238-01C

Image 24
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingVent Specific venting clearancesLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationMale Female Slots Locking Lugs CenterVent Cap Wood Screw Interior Wall Surface Firestop Vent CapHorizontal Vent PipeHorizontal Termination Configurations Recommended Applications Corner ground floor installation Over 12 horizontal pipeTermination is possible Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Roof Flashing Wall Strap Elbow Ceiling FirestopVertical Termination Configurations Elbow Into inner collar fireplace as shownHigh Altitude Installation Venting Installation Fireplace Installation Check GAS TypeInstalling Optional Blower Accessory Desa 5/8 Pipe & Vent KitsFireplace Installation Model BKT InstallationBy turning knob fully counterclockwise before continuing Decal on the firebox bottom approximately 12 in frontInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections REMOVING/REPLACING Glass DoorRemoving Louver Panels Bubbles forming show a leak. Correct all leaks at onceInstalling Lava Rock and Glowing Embers Cleaning Glass DoorRemoving Glass Door Installing Brick Liner Models BL36DASA and BL36DHASA Wall Switch InstallationOptional Remote Control Replace top and bottom louversWiring Diagram Operating FireplaceLighting Instructions Equipment PilotOperating Optional Blower Accessory To Turn OFF GAS To ApplianceOptional Remote OperationCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Position BL36DHASA for log removalImproper vent configuration Restrictions or obstructionReplacement Parts Service HintsTechnical Service Parts Under WarrantySpecifications Illustrated Parts Breakdown Models KC36NE, VKC36NE, KC36PE and VKC36PEParts List Left Refractory Brick PanelRear Refractory Brick Panel Illustrated Parts Breakdown KEY Part Number Description Accessories Brand ModelDate Purchased Serial Number Industrial Drive Box Bowling Green, KY 116238-01C Warranty Information Model Serial No Date PurchasedIndustrial Drive P.O. Box

(V)KC36PE specifications

The Desa (V)KC36PE is a remarkable heating and air conditioning solution designed for both residential and commercial applications. At its core, the unit combines contemporary technology with user-friendly features, making it a popular choice among homeowners and business owners alike.

One of the standout characteristics of the Desa (V)KC36PE is its energy efficiency. The unit operates using advanced refrigerant technologies that allow for optimal cooling and heating while consuming less power. This efficiency not only lowers energy bills but also contributes to a smaller carbon footprint, aligning with global sustainability goals.

The Desa (V)KC36PE features a powerful inverter compressor. This technology adjusts the speed of the compressor to maintain the desired temperature without frequent on-and-off cycles, resulting in quieter operation and enhanced durability. The inverter system also minimizes temperature fluctuations, ensuring a consistent indoor climate.

Ease of use is another essential aspect of the Desa (V)KC36PE. The unit comes equipped with a sleek, intuitive control panel, allowing users to adjust settings effortlessly. Many models also include a remote control and smart connectivity options, enabling users to monitor and manage their heating and cooling systems through mobile applications.

In terms of design, the Desa (V)KC36PE boasts a modern aesthetic that can seamlessly blend into various interior styles. Its compact size makes it suitable for installation in tight spaces without sacrificing performance. Additionally, the unit includes advanced air filtration systems that improve indoor air quality by removing dust, allergens, and other pollutants, ensuring a healthy living environment.

The unit is manufactured with durability in mind, employing high-quality materials that withstand the rigors of daily use. Its weather-resistant casing makes it suitable for various climates, ensuring performance stability throughout the seasons.

Overall, the Desa (V)KC36PE stands out due to its energy-efficient operation, innovative technology, user-friendly features, and robust design. Whether for residential or commercial use, it offers an effective solution for maintaining comfortable indoor environments all year round, highlighting Desa's commitment to quality and customer satisfaction.