Desa (V)KC36PE installation manual Specifications

Page 29

SPECIFICATIONS

29

SPECIFICATIONS

Btu

23,000/33,000 Btu/hr

22,000/31,000 Btu/hr

Gas Type

Natural

Propane/LP

Ignition

Electronic

Electronic

Manifold Pressure

3.5" w.c.

10.0" w.c.

Minimum Inlet Supply Pressure

5.5" w.c.

11.0" w.c.

Dimension, Inches/mm (HxWxD)

 

 

Fireplace (Actual size of

 

 

firebox. Measurements do not

36" x 41" x 21 1/8"

36" x 41" x 21 1/8"

include nailing flanges or

914 x 1041 x 537 mm

914 x 1041 x 537 mm

standoffs).

 

 

Carton

38" x 44" x 22"

38" x 44" x 22"

 

965 x 1118 x 559 mm

965 x 1118 x 559 mm

Weight, lbs/kg*

 

 

Fireplace

165 lbs/75 kg

165 lbs/75 kg

Shipping

168 lbs/76 kg

168 lbs/76 kg

 

 

 

116238-01C

www.desatech.com

Image 29
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesVent Specific venting clearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningMale Female Slots Locking Lugs CenterInterior Wall Surface Firestop Vent Cap Vent Cap Wood ScrewHorizontal Vent PipeHorizontal Termination Configurations Termination is possible Recommended Applications Corner ground floor installationOver 12 horizontal pipe Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationConnect a section of pipe and extend up through the hole Roof Flashing Wall Strap Elbow Ceiling FirestopElbow Into inner collar fireplace as shown Vertical Termination ConfigurationsHigh Altitude Installation Fireplace Installation Check GAS Type Venting InstallationInstalling Optional Blower Accessory Desa 5/8 Pipe & Vent KitsModel BKT Installation Fireplace InstallationBy turning knob fully counterclockwise before continuing Decal on the firebox bottom approximately 12 in frontInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System REMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Louver Panels Bubbles forming show a leak. Correct all leaks at onceRemoving Glass Door Installing Lava Rock and Glowing EmbersCleaning Glass Door Wall Switch Installation Installing Brick Liner Models BL36DASA and BL36DHASAOptional Remote Control Replace top and bottom louversOperating Fireplace Wiring DiagramLighting Instructions Equipment PilotTo Turn OFF GAS To Appliance Operating Optional Blower AccessoryOptional Remote OperationGlass Door Cleaning MaintenancePilot and Burners LogsTroubleshooting BL36DHASA for log removal PositionImproper vent configuration Restrictions or obstructionService Hints Replacement PartsTechnical Service Parts Under WarrantySpecifications Models KC36NE, VKC36NE, KC36PE and VKC36PE Illustrated Parts BreakdownRear Refractory Brick Panel Parts ListLeft Refractory Brick Panel Illustrated Parts Breakdown KEY Part Number Description Accessories Date Purchased Serial Number BrandModel Industrial Drive Box Bowling Green, KY 116238-01C Industrial Drive P.O. Box Warranty InformationModel Serial No Date Purchased

(V)KC36PE specifications

The Desa (V)KC36PE is a remarkable heating and air conditioning solution designed for both residential and commercial applications. At its core, the unit combines contemporary technology with user-friendly features, making it a popular choice among homeowners and business owners alike.

One of the standout characteristics of the Desa (V)KC36PE is its energy efficiency. The unit operates using advanced refrigerant technologies that allow for optimal cooling and heating while consuming less power. This efficiency not only lowers energy bills but also contributes to a smaller carbon footprint, aligning with global sustainability goals.

The Desa (V)KC36PE features a powerful inverter compressor. This technology adjusts the speed of the compressor to maintain the desired temperature without frequent on-and-off cycles, resulting in quieter operation and enhanced durability. The inverter system also minimizes temperature fluctuations, ensuring a consistent indoor climate.

Ease of use is another essential aspect of the Desa (V)KC36PE. The unit comes equipped with a sleek, intuitive control panel, allowing users to adjust settings effortlessly. Many models also include a remote control and smart connectivity options, enabling users to monitor and manage their heating and cooling systems through mobile applications.

In terms of design, the Desa (V)KC36PE boasts a modern aesthetic that can seamlessly blend into various interior styles. Its compact size makes it suitable for installation in tight spaces without sacrificing performance. Additionally, the unit includes advanced air filtration systems that improve indoor air quality by removing dust, allergens, and other pollutants, ensuring a healthy living environment.

The unit is manufactured with durability in mind, employing high-quality materials that withstand the rigors of daily use. Its weather-resistant casing makes it suitable for various climates, ensuring performance stability throughout the seasons.

Overall, the Desa (V)KC36PE stands out due to its energy-efficient operation, innovative technology, user-friendly features, and robust design. Whether for residential or commercial use, it offers an effective solution for maintaining comfortable indoor environments all year round, highlighting Desa's commitment to quality and customer satisfaction.