Desa (V)KC36PE installation manual Illustrated Parts Breakdown

Page 32

32

ILLUSTRATED PARTS BREAKDOWN

Models KC36NE, VKC36NE, KC36PE, VKC36PE

ILLUSTRATED PARTS

BREAKDOWN

BURNER ASSEMBLY FOR MODELS

KC36NE, VKC36NE, KC36PE AND VKC36PE

12

1

2

7

10

 

20

15

19

 

 

18

 

17

13

 

 

 

 

4

 

 

 

 

 

5

 

 

21

9

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

23

 

 

17

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

11

12

 

 

24

 

14

 

 

 

 

 

 

 

 

 

8

31

33

32

 

 

26

 

 

30

 

 

 

 

 

25

 

 

 

 

 

 

 

 

 

28

 

27

 

 

 

 

 

 

 

29

 

 

 

3

12

6

16

www.desatech.com

116238-01C

Image 32
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingVent Specific venting clearancesLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationMale Female Slots Locking Lugs CenterVent Cap Wood Screw Interior Wall Surface Firestop Vent CapHorizontal Vent PipeHorizontal Termination Configurations Termination is possible Recommended Applications Corner ground floor installationOver 12 horizontal pipe Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Roof Flashing Wall Strap Elbow Ceiling FirestopVertical Termination Configurations Elbow Into inner collar fireplace as shownHigh Altitude Installation Venting Installation Fireplace Installation Check GAS TypeInstalling Optional Blower Accessory Desa 5/8 Pipe & Vent KitsFireplace Installation Model BKT InstallationBy turning knob fully counterclockwise before continuing Decal on the firebox bottom approximately 12 in frontInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections REMOVING/REPLACING Glass DoorRemoving Louver Panels Bubbles forming show a leak. Correct all leaks at onceRemoving Glass Door Installing Lava Rock and Glowing EmbersCleaning Glass Door Installing Brick Liner Models BL36DASA and BL36DHASA Wall Switch InstallationOptional Remote Control Replace top and bottom louversWiring Diagram Operating FireplaceLighting Instructions Equipment PilotOperating Optional Blower Accessory To Turn OFF GAS To ApplianceOptional Remote OperationCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Position BL36DHASA for log removalImproper vent configuration Restrictions or obstructionReplacement Parts Service HintsTechnical Service Parts Under WarrantySpecifications Illustrated Parts Breakdown Models KC36NE, VKC36NE, KC36PE and VKC36PERear Refractory Brick Panel Parts ListLeft Refractory Brick Panel Illustrated Parts Breakdown KEY Part Number Description Accessories Date Purchased Serial Number BrandModel Industrial Drive Box Bowling Green, KY 116238-01C Industrial Drive P.O. Box Warranty InformationModel Serial No Date Purchased

(V)KC36PE specifications

The Desa (V)KC36PE is a remarkable heating and air conditioning solution designed for both residential and commercial applications. At its core, the unit combines contemporary technology with user-friendly features, making it a popular choice among homeowners and business owners alike.

One of the standout characteristics of the Desa (V)KC36PE is its energy efficiency. The unit operates using advanced refrigerant technologies that allow for optimal cooling and heating while consuming less power. This efficiency not only lowers energy bills but also contributes to a smaller carbon footprint, aligning with global sustainability goals.

The Desa (V)KC36PE features a powerful inverter compressor. This technology adjusts the speed of the compressor to maintain the desired temperature without frequent on-and-off cycles, resulting in quieter operation and enhanced durability. The inverter system also minimizes temperature fluctuations, ensuring a consistent indoor climate.

Ease of use is another essential aspect of the Desa (V)KC36PE. The unit comes equipped with a sleek, intuitive control panel, allowing users to adjust settings effortlessly. Many models also include a remote control and smart connectivity options, enabling users to monitor and manage their heating and cooling systems through mobile applications.

In terms of design, the Desa (V)KC36PE boasts a modern aesthetic that can seamlessly blend into various interior styles. Its compact size makes it suitable for installation in tight spaces without sacrificing performance. Additionally, the unit includes advanced air filtration systems that improve indoor air quality by removing dust, allergens, and other pollutants, ensuring a healthy living environment.

The unit is manufactured with durability in mind, employing high-quality materials that withstand the rigors of daily use. Its weather-resistant casing makes it suitable for various climates, ensuring performance stability throughout the seasons.

Overall, the Desa (V)KC36PE stands out due to its energy-efficient operation, innovative technology, user-friendly features, and robust design. Whether for residential or commercial use, it offers an effective solution for maintaining comfortable indoor environments all year round, highlighting Desa's commitment to quality and customer satisfaction.