Desa (V)VC42PE, (V)VC42NE installation manual Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

PRODUCT IDENTIFICATION

3

LOCAL CODES

3

PRODUCT FEATURES

4

PRE-INSTALLATION PREPARATION

4

LOCATION OF TERMINATION CAP

6

VENTING INSTALLATION INSTRUCTIONS

7

FIREPLACE INSTALLATION

16

WIRING DIAGRAM

23

OPERATING FIREPLACE

23

INSPECTING BURNERS

24

CLEANING AND MAINTENANCE

25

TROUBLESHOOTING

26

REPLACEMENT PARTS

28

SERVICE HINTS

28

TECHNICAL SERVICE

28

SPECIFICATIONS

29

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

30

ACCESSORIES

34

OWNER'S REGISTRATION CARD

35

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace must be installed by a qualified (certified or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air for combustion through the outer pipe and combustion gases are exhausted through the inner pipe. If the glass door assembly and venting pipe are not properly seated, connected and sealed, carbon monoxide leakage (spillage) can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and ser- viced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol and those at high altitudes.

Propane/LP and Natural Gas: Propane/LP and natural gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use pro- pane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighborʼs phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

4.Never install the fireplace

in a recreational vehicle

in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front

in high traffic areas

www.desatech.com

116237-01A

Image 2
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Venting Installation Instructions Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Vertical V Horizontal H Min Max 12 max 18 max 20 maxHigh Altitude Installation Installing Optional Blower Accessory Venting InstallationFireplace Installation Check GAS Type Desa 5/8 Pipe & Vent KitsFireplace Installation Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Removing Louver Panels Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Removing Glass Door Installing Lava Rock and Glowing EmbersCleaning Glass Door Optional Remote Control Installation Model WRC Installing Brick Liner Models BL42DASA and BL42DHASAWall Switch Installation Lighting Instructions Wiring DiagramOperating Fireplace Optional Remote Operating Optional Blower AccessoryTo Turn OFF GAS To Appliance OperationPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Technical Service Replacement PartsService Hints Parts Under WarrantySpecifications Illustrated Parts Breakdown Models VC42NE, VC42PE, VVC42NE and VVC42PEParts List KEY Part Number Description QTY19 18 116237-01A KEY Part Number Description Accessories Owners Registration Form Postage Required 116237-01A Warranty Information Keep this Warranty

(V)VC42PE, (V)VC42NE specifications

Desa (V)VC42NE and (V)VC42PE are innovative heating solutions that cater to modern residential and commercial spaces. These advanced units embody a combination of efficiency, sustainability, and user-friendly features, making them highly sought after in the market.

The (V)VC42NE model stands out for its high energy efficiency, designed to provide optimal heating performance while minimizing energy consumption. This unit incorporates state-of-the-art condensing technology, which allows it to extract additional heat from exhaust gases, enhancing its overall energy efficiency. With a commendable seasonal efficiency rating, it is suitable for environments where reduced carbon footprints are a priority.

On the other hand, the (V)VC42PE model is engineered to offer unparalleled versatility. It supports a range of fuel options, including natural gas and propane, making it adaptable to various installations. This flexibility is particularly beneficial for users who may want to switch fuel sources in the future. The (V)VC42PE also includes a powerful fan system, which ensures even heat distribution throughout the space, eliminating cold spots.

Both models are equipped with advanced safety features that comply with stringent industry standards. These include flame failure devices, pressure relief valves, and overheat protection systems that ensure the units operate safely under all conditions. Additionally, they are designed for low maintenance, with accessible components that simplify servicing and repairs.

One of the standout characteristics of both Desa models is their intuitive control systems. The units feature digital thermostats that allow users to set and monitor temperatures effortlessly. Moreover, they offer programmable settings that enable users to optimize heating schedules according to their lifestyle needs. This feature contributes to enhanced comfort while further promoting energy savings.

In terms of design, both the (V)VC42NE and (V)VC42PE models possess a sleek, modern aesthetic that integrates seamlessly into various interior styles. Their compact size allows for easy installation in tight spaces, making them an ideal choice for apartments, offices, and other limited areas.

In summary, Desa (V)VC42NE and (V)VC42PE units are exemplary heating systems that combine efficiency, safety, and user-friendly features, making them suitable for a wide range of applications. With their advanced technologies and commitment to sustainability, these models are poised to meet the demands of today's energy-conscious consumers.