INSTALLATION

CAUTION: Do not remove the metal data plates attached to the burner pan. The data plates contain important warranty in- formation.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue for damage.

NOTICE: Installation, service, and

MODEL

 

DESCRIPTION

 

 

Btu Input

 

Btu Input

Minimum

 

 

 

Natural Gas

Propane Gas

Vent Opening

 

 

 

 

 

 

 

 

 

 

 

 

VVSR18

 

18" Single Burner

 

50,000

40,000

8" dia.

VVSR24

 

24" Single Burner

 

60,000

50,000

8" dia.

VVDR18

 

18" Dual Burner

 

55,000

45,000

8" dia.

VVDR24

 

24" Dual Burner

 

65,000

55,000

8" dia.

VVDR30

 

30" Dual Burner

 

70,000

60,000

8" dia.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM FIREBOX SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG

FRONT

BACK

 

 

 

 

 

 

 

 

 

SIZE

WIDTH*

WIDTH**

 

DEPTH

 

HEIGHT

 

 

18"

 

28"

16"

 

 

14"

 

18"

 

 

 

24"

29 3/4"

17"

 

15 1/2"

 

18"

 

 

 

30"

 

36"

27"

 

 

18"

 

18"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Add 6" if safety valve/pilot is used **At depth indicated

repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliance. Only fac- tory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and

FUEL INLET PRESSURE SPECIFICATIONS ("W.C.)

 

Min.

Max.

 

NG

5.5

10.5

 

 

 

 

 

LP

11

13

 

 

 

 

 

BURNER ORIFICE

LOG

NATURAL

PROPANE/LP

SIZE

IN.

NUM.

IN.

NUM.

18"

.1285

30

.076

48

24"

.144

27

.086

44

30"

.154

23

.089

43

 

 

 

 

 

all codes and requirements of the authority having jurisdiction. Any

Figure 4 - Technical Information Charts

modifications to this kit, or use of unauthorized components or ac- cessory items will void the manufacturer’s warranty, and may result in a hazardous condition.

FLUE OPENING

SPECIFICATIONS

Note: This vented appliance must be in- stalled only in a solid-fuel burning fireplace with a working flue and constructed of non- combustible material.

The charts in Figure 4 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable be- fore installation is attempted.

The fireplace must include a working flue and venting system with the minimum open- ings shown in the Figure 4.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you must install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 20). Call dealer where you bought log set.

If the fireplace does not have a gas supply shut-off valve, one must be installed.

VENTING SPECIFICATIONS FOR INSTALLATION

The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled news- paper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue must remain open a mini- mum of 3" at all times during the operation of this log set.

Continued

901265

7

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Use with Log Sets Radco Burners For Vented Natural GAS Logs Safety InformationRemote Control Accessories Product Identification Optional Product FeaturesON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP Conversion Remote Control Ready Millivolt Safety VALVE/ Pilot KITConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Appliance Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingCheck GAS Type InstallationFlue Opening Specifications Venting Specifications for InstallationPressure Testing Gas Supply Piping System Installing Damper ClampConnecting to GAS Supply Installation Items NeededInstallation and Gas Connection Hearth KIT Assembly and InstallationOptional GA9000 ON/OFF Safety VALVE/PILOT KIT Assembly Kit AssemblyBurner Inlet Fitting Propane/LP Gas ConversionChanging Pilot Orifice Testing Burner for LeaksInstalling the Grate and Logs Adding PAN MaterialOperating Appliance To Turn OFF GAS To Appliance TroubleshootingShutting Off Burner Only pilot stays lit Gas leak. See Warning statement at TopClean pilot see Cleaning and Mainte Illustrated Parts Breakdown Radco Burner Models VVSR18 VVSR24, VVDR18 VVDR24, and VVDR30 Parts ListLOG SET Models VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 Parts List Replacement Parts Cleaning and MaintenanceAccessories Ornamental Grate Enhancer GA9330 Decorative ASH BED Control Cover DabkOrnamental Grate Enhancer GA9310 Ornamental Grate Enhancer GA9320Radco Burners For Vented Natural GAS Logs 901265 International Warranty Information