12
INSTALLATION
Optional Wireless
INSTALLATION
Continued
4.Connect wires to control circuit. Connect white wire to termi- nal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety circuit wiring (see Wiring Diagram, page 20).
5.Locate the battery clip mounted on the back of the receiver (see Figure 16).
6.Slide
7.Attach the terminal wires to the battery (see Figure 16).
8.Replace refractory brick access panel.
| ||
Battery | Receiver | |
Clip | ||
| ||
Terminal |
| |
Wires |
|
Figure 16 - Installing Battery in Receiver
Installing 9-Volt Battery in Hand-Held Remote Control Unit
1.Remove battery cover on back of remote control unit.
2.Attach terminal wires to the battery (not included). Place bat- tery into the battery housing. Note: Only use alkaline battery.
3.Replace battery cover onto remote control unit.
GAS LINE HOOK-UP
WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.
WARNING: Before you proceed, make sure your gas supply is OFF.
A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 18.
In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from any of the 3 directions shown in Figure 19.
CAUTION: Do not kink flexible gas line.
Typical Exterior Wall Gas | Shutoff |
Shutoff Installation | Valve |
Key |
|
| Extension |
Figure 18 - Manual Shutoff Valve Installation
Battery | Remote |
Cover | Control Unit |
Terminal Wires
9-Volt Battery
Battery
Housing
1/2" NPT Incoming
Black Iron Gas Line
A
7"
7"
Alternate Gas Supply Through
Flexible Gas Line
(1 Provided) Can
Be Extended Out
Either Side
B
Figure 17 - Installing Battery in Hand-Held Remote Control Unit
| M36(B,H)/VM36(B,H) | M42(B,H)/VM42(B,H) |
A | 8 5/8" (219mm) | 10 1/2" (267mm) |
B | 11" (279mm) | 12 3/4" (324mm) |
Figure 19 - Routing Incoming Gas Line
For morevisit www..com