INSTALLATION

Log Placement for M42 Models

15

INSTALLATION

Continued

LOG PLACEMENT FOR M42/VM42 MODELS

1.Place log 1A on the front left side of grate. Place log 1B on the front right side of the grate. See Figure 29.

2.Place large back log (log 2) onto grate making sure notches rest over grate. Insert peg on back of log 1A into hole on front left of log 2 (see Figure 29).

3.Place log 3 across log 1A and log 2, aligning peg on log 3 with top left hole on log 2 (see Figure 30).

4.Align peg on log 4 with inside left hole on log 2 (see Figure 30). Log 4 will rest on grate fingers as shown in Figure 31.

5.Align peg on log 5 with the inside right hole on log 2 (see Figure 31). Rest the lower part of log 5 on the log 4 and on grate as shown in Figure 32.

6.Align peg at the top of log 6 with outside right hole on log 2. Fit the peg at the lower part of log 6 into the hole on top of log 1B (see Figures 31 and 32).

To enhance the look of the hearth you may optionally place the lava rock provided around the front and sides of the burner pan.

NOTICE: Do not put lava rock inside the burner pan or around the air mixer fitting. Placing lava rock inside the burner pan or blocking the openings of the propane/LP air-mixer could cause performance problems.

Log 1A

Log 2

Log 3

Log 4

Log 1A

Figure 30 - Installing Logs 3 and 4

Log 4

Log 2

Log 1B

Log 5

Log 6

Log 2

Log 1B

Figure 31 - Installing Logs 5 and 6

Log 1B

Figure 29 - Installing Logs 1A, 1B and 2

Figure 32 - Logs Installed for M42 /VM42 Models

 

For more information, visit www.desatech.com

108795

Image 15
Contents What to do if YOU Smell GAS For Your SafetyVent Decorative GAS Fireplace Natural GASSafety Information Table of ContentsUnpacking Introduction Before YOU BeginM36B,H/VM36B,H M42B,H/VM42B,H Model Product SpecificationsPRE-INSTALLATION Preparation Selecting LocationClearances M36B,H M42B,H VM36B,H VM42B,H Mantel Clearances and Wall DetailsM36B,H M42B,H VM36B,H VM42B,HFraming Installing Transition Pipe and Starter CollarTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingInstalling Receiver InstallationWall Switch Installation Optional Wireless HAND-HELD Remote Control InstallationGAS Line HOOK-UP Installing 9-Volt Battery in Hand-Held Remote Control UnitOvertighten Ember and PAN Material PlacementInstalling Logs 1 LOG Placement for M36/VM36 ModelsInstalling Logs 1A, 1B LOG Placement for M42/VM42 ModelsInstalling Optional Glass Door Accessory Combustion AIR KIT Model AK4 OptionalAppliance Enclosure Removing Glass Doors Opening Vent DamperTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Pilot AssemblyInspecting Burners Optional HAND-HELD Remote OperationReplacement Parts Cleaning Maintenance Technical ServiceWiring Diagram Service HintsObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Gas leak. See Warning statement at TopVM42B,H Models Illustrated Parts BreakdownM36B,H, M42B,H, VM36B,H and VM42B,H Models Parts ListLogs for M36B,H, M42B,H, VM36B,H and VM42B,H Models Logset for M36B, H/VM36B, H ModelsLogset for M42B, H/VM42B, H Models Accessories Warranty Information