TROUBLESHOOTING

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

23

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, etc. (See IMPORTANT

 

 

statement above)

 

2.

For propane/LP gas, low fuel supply

 

3.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor caus- ing products while fireplace is running

2.Contact local propane/LP supplier

3.Locate and correct all leaks (see Gas Line Hook-Up, pages 12 and 13)

Gas odor even when control knob is in OFF 1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Gas

position

top of page

 

Line Hook-Up, pages 12 and 13)

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Gas Line Hook-Up, pages 12 and 13)

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets. Pe-

 

 

 

 

riodically repeat as needed

 

3.

Burner flame holes blocked

3.

Remove blockage or replace burner

 

4.

Improper venting or excessive blockage

4.

Have the vent system inspected, includ-

 

 

 

 

ing the termination cap. Remove any

 

 

 

 

restrictions or obstruction

 

5.

Excessive amounts of embers and pan

5.

Clear excess embers until a minimum

 

 

material

 

gap of 1/2" remains under the grate

For more information, visit www.desatech.com

108795

Image 23
Contents What to do if YOU Smell GAS For Your SafetyVent Decorative GAS Fireplace Natural GASSafety Information Table of ContentsUnpacking M36B,H/VM36B,H M42B,H/VM42B,H IntroductionBefore YOU Begin Model Product SpecificationsClearances PRE-INSTALLATION PreparationSelecting Location M36B,H M42B,H VM36B,H VM42B,H Mantel Clearances and Wall DetailsM36B,H M42B,H VM36B,H VM42B,HFraming Installing Transition Pipe and Starter CollarTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingInstalling Receiver InstallationWall Switch Installation Optional Wireless HAND-HELD Remote Control InstallationGAS Line HOOK-UP Installing 9-Volt Battery in Hand-Held Remote Control UnitOvertighten Ember and PAN Material PlacementInstalling Logs 1 LOG Placement for M36/VM36 ModelsInstalling Logs 1A, 1B LOG Placement for M42/VM42 ModelsAppliance Enclosure Installing Optional Glass Door AccessoryCombustion AIR KIT Model AK4 Optional Removing Glass Doors Opening Vent DamperTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Pilot AssemblyInspecting Burners Optional HAND-HELD Remote OperationReplacement Parts Cleaning Maintenance Technical ServiceWiring Diagram Service HintsObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Gas leak. See Warning statement at TopVM42B,H Models Illustrated Parts BreakdownM36B,H, M42B,H, VM36B,H and VM42B,H Models Parts ListLogset for M42B, H/VM42B, H Models Logs for M36B,H, M42B,H, VM36B,H and VM42B,H ModelsLogset for M36B, H/VM36B, H Models Accessories Warranty Information