OPERATING APPLIANCE

Continued

Shutting Off Appliance

Turn gas shutoff valve clockwise to the OFF position.

CURING

LOGS

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

Ignite a 2" flame and maintain it for 1 hour.

Burn the logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.

OPERATING

INSTRUCTIONS

FOR GA9050A

Note: Operation instructions for GA9150A Remote Ready Valve/Pilot Kit will be included with the kit.

1.STOP! Read the safety information, page 10.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! Refer to the National Fuel Gas Codes, ANSI Z233.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation. If you donʼt smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position and press in. Keep control knob pressed in for five (5) seconds. Note: You may be running this log set for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise to the ON position. Burner should light. If burner does not light, call a qualified service person.

Control Knob

Ignitor Pilot

 

ON

 

OFF

 

 

FROM "PILOT" POSITION

 

On

SLIGHT PUSH TO

Off

 

PULL PUSH

 

 

TURN OFF

 

ON OFF FROM "PILOT" POSITION SLIGHT PUSH TO TURN OFF PULL PUSH

TO LIGHT

ON OFF FROM "PILOT" POSITION

TO LIGHT

SLIGHT PUSH TO TURN OFF PULL PUSH TO LIGHT

Figure 12 - Ignitor and Control Knob

 

Thermocouple

Pilot

 

 

 

 

Burner

 

 

 

 

Figure 13 - Thermocouple and Pilot

TO TURN OFF GAS

 

TO APPLIANCE

 

 

Shutting Off Appliance

 

 

 

 

1.Turn control knob clockwise to the PILOT position.

2.Press in and turn control clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

 

115043-01C

www.desatech.com

11

Image 11
Contents Models LCF18 and LCF24 BrentwoodTable of Contents Safety Information Local Codes Product IdentificationOptional Product Features UnpackinginstallationConnecting to GAS Supply InstallationVenting Specifications for Installation Installing Damper ClampTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Hearth KIT Assembly and Installation Installation and Gas Connection Adding PAN Material Optional GA9050A ON/OFF Safety VALVE/PILOT KITTesting Burner for Leaks Installing the Grate and LogsLighting Instructions For Your Safety Read Before LightingFlame Adjustment Operating ApplianceShutting Off Appliance Curing LogsOperating Instructions For GA9050A Replacement Parts Cleaning MaintenanceService Hints Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingWhen ignitor button is pressed Gas leak. See Warning Illustrated Parts Breakdown Parts List Equipment Shutoff Valve GA5010 AccessoriesReceiver and HAND-HELD ON/OFF Remote Control KIT HRC101 Manual Control ON/OFF Safety VALVE/PILOT KIT GA9050A115043-01C Limited Warranty Vented GAS Logs Warranty InformationKeep this Warranty