Desa LCF24, LCF18 Optional GA9050A ON/OFF Safety VALVE/PILOT KIT, Testing Burner for Leaks

Page 9

INSTALLATION

Continued

OPTIONAL GA9050A ON/OFF SAFETY VALVE/PILOT KIT

For additional convenience and safety, or for propane/LP conversion, an optional ON/OFF safety valve/pilot kit is available. See Accessories, page 18.

WARNING: You must use a ON/OFF safety valve/pilot kit for propane/LP conversion.

TESTING BURNER FOR LEAKS

1.Generously apply noncorrosive leak detec- tion fluid to all connections.

WARNING: Never check for gas leaks with open flame.

2.Light the burner with the shutoff valve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 10).

3.Inspect all connections for bubbles, raw gas odor, or flame from any area other than the burner (leaks). If leaks are detected, shut off the gas valve immediately. Tighten, or reas- semble the loose connection(s) using pipe joint compound until burner system is leak free.

4.When the burner is tested and leak free, observe the individual tongues of flame on the burner. Note: The burner design includes more ports on the outside of the bar. Make sure that all ports are clear and producing flame evenly across the burner. If any ports appear blocked, clear them by removing the burner manifold and reaming the ports with a modified paper clip or other suitable tool.

5.When finished testing, turn the gas shutoff valve OFF to extinguish all flames.

ADDING PAN MATERIAL

1.Open the bag of ash bed material (vermiculite) and spread it evenly across the burner pan to the top. You may overflow the front and sides of the pan to cover the entire pan and connecting hardware. Do not cover GA9050A or GA9150A valve.

2.Open the glowing embers and evenly cover the ash bed material (vermiculite) in the burner pan.

INSTALLING THE GRATE AND LOGS

1.Place the grate over the burner pan where the two outer horizontal supports on the grate fit into the two pan positioning notches in the rear vertical edge of the pan.

2.Slide the two rear log grate steps over the two outer horizontal supports on the grate as shown in Figure 8.

3.Place the back log onto the grate steps (see Figure 9).

4.Place the front log(s) on the grate and slide forward against the front bars on the grate (see Figure 9).

5.Place three middle logs on top of bottom logs (see Figure 10, page 10).

6.Place the smaller top logs onto the bottom logs (see Figure 11, page 10). Leave as much open space between logs as possible to minimize flame impingement and sooting. Note: Logs may chip if they are handled roughly or if hit together while being placed.

Grate Steps

Grate

Figure 8 - Installing Grate (Pan Material

Not Shown)

Figure 9 - Installing Bottom Logs

115043-01C

www.desatech.com

9

Image 9
Contents Models LCF18 and LCF24 BrentwoodTable of Contents Safety Information Local Codes Product IdentificationOptional Product Features Unpackinginstallation Venting Specifications for Installation Installation Installing Damper Clamp Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsHearth KIT Assembly and Installation Installation and Gas ConnectionTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Testing Burner for Leaks Optional GA9050A ON/OFF Safety VALVE/PILOT KITInstalling the Grate and Logs Adding PAN MaterialFlame Adjustment For Your Safety Read Before LightingOperating Appliance Lighting InstructionsCuring Logs Operating Instructions For GA9050AShutting Off Appliance Service Hints Cleaning MaintenanceTechnical Service Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingWhen ignitor button is pressed Gas leak. See Warning Illustrated Parts Breakdown Parts List Receiver and HAND-HELD ON/OFF Remote Control KIT HRC101 AccessoriesManual Control ON/OFF Safety VALVE/PILOT KIT GA9050A Equipment Shutoff Valve GA5010115043-01C Warranty Information Keep this WarrantyLimited Warranty Vented GAS Logs