TROUBLESHOOTING

Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are:

1.Loose wiring connections

2.Construction debris clogging the pilot and/or gas control valve filter

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Ignitor will not spark or pilot will not light

1.No gas supply or shutoff valve is OFF

2.Air in gas line

3.Construction debris clog- ging pilot orifice

4.Low gas pressure

5.Kinked pilot line

6.Control valve knob is not opening

7.No power to unit or the ignition module or power transformer is bad

8. Vent damper not fully open

1.Check to see if you have gas supply and that equipment shutoff valve is opened

2.Repeat lighting procedure sev- eral times to purge all air out of lines. If after repeated attempts appliance does not light, call for qualified service and repair.

3.Remove debris and dirt, in- spect and clean any other possible obstructions

4.Contact your gas supplier to check pressure

5.Have a qualified technician replace pilot line

6.Replace control valve (Refer to Replacement Parts, page 20)

7.Check that main power is on and that all wire connections are made correctly to the ignition model (see Wiring Diagram, page 21). Check for 24 VAC at the secondary side of the transformer. If 24 VAC is present and the module does not operate, have the module replaced otherwise have the transformer replaced

8.Open vent damper until fully locked in OPEN position

Pilot will not stay lit

1.

Loose wiring on ignitor wire

 

 

to ignition module and/or poor

 

 

ground to ignition module

 

2.

Pilot flame too low to sense

1.Check wiring connection. Refer to wiring diagram (see Wiring Diagram, page 21) and/or check ground wire to ignition module

2.Clean and adjust pilot burner and check gas supply and inlet

pressure to unit

Note: Have a qualified technician replace pilot assembly if broken or corroded

No gas to burner, although wall

1.

Wall switch wires defective or

1.

Check electrical connections

switch and valve are set to the

 

too long

2.

Recheck problems 1 and 2

ON position

2.

Thermopile not generating

 

 

sufficient voltage

 

 

22

www.desatech.com

108796-01K

Image 22
Contents For Your Safety Table of Contents Safety Information High traffic areas Windy or drafty areasIntroduction UnpackingBefore YOU Begin Possible Locations for Installing Appliance Selecting LocationProduct Specifications M36EB,H M42EB,HMantel Clearances and Wall PRE-INSTALLATION PreparationClearances DetailsRough Opening for Installing Wall FramingInstalling Transition Pipe and Starter Collar Venting InstallationVent Piping Starter Collar Transition Pipe Vent Collar Typical B-Vent Configuration Roof PitchWall Switch Installation InstallationChecking for Proper Venting M42EPB,H GAS Line HOOK-UPVM36EB,H Ember and PAN Material Placement Log Notch Log 3 Log Notches LOG Placement for M36E, M36EP, VME36 and VM36EP ModelsGrate Pan and Ember Material Burner Pan LogLog Notches LOG Placement for M42E, M42EP, VME42 and VM42EP ModelsNotch Log Log 2A Log 2B Log Notch Log 2BCombustion AIR KIT Model AK4 Optional Installing Optional Glass Door AccessoryAppliance Enclosure Clip Screw Side Front Opening Vent DamperSpring Partially Opened DoorLighting Instructions For Your Safety Read Before LightingOperating Fireplace EquipmentTo Turn OFF GAS To Appliance Pilot AssemblyInspecting Burners Optional Remote OperationTechnical Service Cleaning MaintenanceService Hints Replacement PartsWiring Diagram Pilot Burner Pilot Gas LineTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning Illustrated Parts Breakdown ModelsParts List DescriptionDescription QTY Logsets for Models 108723-01M42B,H, M42PB,H, VM42B,H and VM42PB,H Accessories 108796-01K 108796-01K Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Firebox