INSTALLATION
Continued
3.Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 15). The battery is included
4.Once the battery is activated the unit is ready to use.
5.Replace front refractory access panel.
Battery Cover
12 Volt Battery
Back of
Handset
Pull to Remove
Insulation Tab
Figure 15 - Installing Battery into Back of Handset
GAS LINE HOOK-UP
WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.
WARNING: Before you pro- ceed, make sure your gas supply is OFF.
A manual shutoff valve has been included in the applianceʼs gas supply system. You may consider installing an extra gas shutoff valve outside the
DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 18) and into the appliance. Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 19, page 13).
Before connecting the black iron gas line to the inside of the appliance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with local building codes).
Key | Shutoff | |
Valve | ||
|
Extension
Typical Exterior Wall Gas
Shutoff Installation
Figure 16 - Manual Shutoff Valve
Installation
1/2" NPT Incoming |
|
|
| |||
Black Iron Gas Line |
|
|
| |||
| A |
| 7" |
|
| |
|
|
|
|
| ||
|
|
| 7" | Alternate Gas Supply | ||
|
|
|
| |||
|
|
|
| Through | ||
|
| M36E(B,H), | M42E(B,H), | |||
|
| M36EP(B,H | M42EP(B,H) | |||
| VM36E(B,H), | VM42E(B,H), | ||||
A | VM36EP(B,H) | VM42EP(B,H) | ||||
8 | 5 | /8" (219 mm) | 10 | 1 | /2" (267 mm) | |
|
|
|
|
| ||
Figure 17 - Routing Incoming Gas Line |
applianceʼs enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 16.
In conformance with local codes, route a 1/2" NPT gas line to the appliance through hole in left side of firebox or
Sediment
Trap (Not
Supplied)
3" Min.
(76 mm)
| Incoming |
| 1/2" Gas Line |
| Permitted by |
| Local Codes |
| all |
| W |
Side | |
Of | Appliance |
|
CAUTION: Do not kink flex- ible gas line.
Figure 18 - Sediment Trap
12 | www.desatech.com |