Desa LFP33NR installation manual Unvented VENT-FREE Natural GAS Fireplace

Page 1

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

LFP33NR

REMOTE READY

GAS FIREPLACE

SYSTEM

Shown with optional cabinet mantel and hearth base.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional infor- mation consult a qualified in- staller, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation sec- tion on page 4 of this manual.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS Unvented VENT-FREE Natural GAS FireplaceLFP33NR Unvented Natural GAS Fireplace Safety InformationProduct Identification Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Optional Blower Accessory InstallationCheck GAS Type Electrical HookupMinimum Wall and Ceiling Clearances see Figure Conventional Fireplace InstallationLocation of Nailing Flanges BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Removing Log Base Assembly From Fireplace Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Screen Installing LogsInstalling Batteries for RM4 Optional Wireless HAND- Held Remote Control Accessory RM4Installing Remote Receiver Unit Installing Batteries in Hand-Held Remote Control UnitInstalling Battery in Receiver Installing Batteries for Ghrc and Ghrct SeriesInstalling Battery in Hand-Held Remote Control Unit Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Optional Blower OperationInspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Service Hints Wiring DiagramTechnical Service Specifications Parts Under Warranty Replacement PartsParts not Under Warranty Parts CentralCorner Mantel AccessoriesGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Medium Stained Oak VeneerReceiver and HAND- Held Remote Control KIT Cghrc Series HAND-HELD Remote Control RM4Blower Accessories Manual Shutoff Valve GA5010Remote Ready Model LFP33NR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFireplace LFP33NR Parts List Warranty Information