Desa LFP33NR To Turn OFF GAS To Appliance, Optional Remote Operation, Optional Blower Operation

Page 17

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor Electrode

Figure 37 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, pages 24 and 25). Follow instructions in- cluded with the remote control.

Thermostat Control Operation

The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 16.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide thee selector switch to the REMOTE po- sition. Note: The burners may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote control unit. Fol- low the instructions supplied with the remote control for additional features.

IMPORTANT: Do not leave the selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/ OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

IMPORTANT: The thermostat is built into the hand-held remote. The remote should be kept several feet from the fire- place and should be pointed towards the fireplace. If placed too close to the fire- place, the remote will sense the room is too hot and turn the fireplace off.

OPTIONAL BLOWER

OPERATION

Locate the blower switch by opening lower louver on fireplace. Blower switch is lo- cated at lower left inside louver door.

Thisthermostat-controlledblowerhasthree settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF position, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Light- ing Instructions, page 16.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, page 16.

Flame Adjustment Knob

 

IH

 

P

 

 

F

IL

 

 

 

O

 

 

F

 

T

 

 

O

 

 

 

 

 

 

 

 

 

O

 

 

 

 

N

ON

 

 

 

 

LO

 

 

 

OFF

REMOTE

Control Knob in

On Position Selector Switch in Remote Position

(Optional Remote Control)

Figure 38 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

104887

17

Image 17
Contents What to do if YOU Smell GAS Unvented VENT-FREE Natural GAS FireplaceLFP33NR Unvented Natural GAS Fireplace Safety InformationProduct Identification Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Optional Blower Accessory InstallationCheck GAS Type Electrical HookupMinimum Wall and Ceiling Clearances see Figure Conventional Fireplace InstallationLocation of Nailing Flanges BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Removing Log Base Assembly From Fireplace Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Screen Installing LogsInstalling Batteries for RM4 Optional Wireless HAND- Held Remote Control Accessory RM4Installing Remote Receiver Unit Installing Batteries in Hand-Held Remote Control UnitInstalling Battery in Hand-Held Remote Control Unit Installing Batteries for Ghrc and Ghrct SeriesInstalling Battery in Receiver Lighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Optional Blower OperationInspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Technical Service Specifications Wiring DiagramService Hints Parts Under Warranty Replacement PartsParts not Under Warranty Parts CentralCorner Mantel AccessoriesGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Medium Stained Oak VeneerReceiver and HAND- Held Remote Control KIT Cghrc Series HAND-HELD Remote Control RM4Blower Accessories Manual Shutoff Valve GA5010Remote Ready Model LFP33NR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFireplace LFP33NR Parts List Warranty Information