OPERATING FIREPLACE
Continued
Figure 26 - Pilot
TO TURN OFF GAS
TO APPLIANCE
1.Turn off all electric power to the appliance if service is to be performed.
2.Remove control access panel.
3.Close the gas valve.
CLEANING AND
MAINTENANCE
WARNING: Installation and repair should be done by a quali- fied service person. The appli- ance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate- rial, pet hair, etc. It is imperative that the control compartments, burners and circulating air sys- tem be kept clean.
WARNING: The logs can be hot. Handle only when cool.
WARNING: Turn off gas and electrical power before servicing appliance. Any safety screen or guard removed for servicing must be replaced prior to operat- ing the appliance.
WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.
Keep control compartment, logs, burner and area surrounding logs clean by vacuuming or brushing at least twice a year. Take care not to alter the set- tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning glass doors and trims. Any household glass cleaner should suffice. Do not clean doors when hot. Allow appliance to cool before cleaning.
TECHNICAL SERVICE
You may have further questions about installation, operation or troubleshooting. If so, contact DESAʼs Technical Service Department at
You can also visit DESAʼs Technical Services web site at www.desatech.com.
SPECIFICATIONS
GL36ST, GL36STE
•Maximum Input Rating at Altitudes: 2,000 ft. - 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800 Btu/hr.
•Manifold Pressure: 3.5 W.C. (.87 kPa)
•Supply Pressure (in. of water): Minimum* - 4.5" (1.12 kPa), Maximum - 11.0" (2.74 kPa)
•Orifice Size at Altitudes: 2,000 ft. - #30, 2,000 ft. to 4,000 ft. - #31
GL36STP, GL36STEP
•Maximum Input Rating at Altitudes: 2,000 ft. - 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800 Btu/hr.
•Manifold Pressure: 11.0 W.C. (2.74 kPa)
•Supply Pressure (in. of water): Minimum* - 12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
•Orifice Size at Altitudes: 2,000 ft. - #49, 2,000 ft. to 4,000 ft. - #51