FIREPLACE
INSTALLATION
Continued
The gas control valve is secured to the burner pan assembly underneath the front ledge. A 1/8" NPT plugged tapping is provided on the gas control valve for a test gauge connection immediately upstream of the gas supply connection to the ap- pliance (see Figures 13 and 14).
Strain Relief |
Grommet |
ON/OFF Knob
| Pilot Gas Line | |
Pilot | Do Not Kink | To Pilot |
| ||
Adjustment | Burner | |
Cap |
|
|
|
| To Main |
|
| Burner |
Common |
Ground Wire |
Figure 12 - Wiring Through Outer Surround
GAS SUPPLY TESTING
Note: This section is intended as a guide for quali- fied technicians installing gas to this appliance.
CAUTION: Do not connect appliance before pressure test- ing gas piping. Damage to gas valve may result and an unsafe condition may be caused.
The appliance and its individual
The appliance must be isolated from the gas sup- ply piping system by closing its individual manual
This unit has been tested for installation at high altitude in accordance with Canadian test stan- dard
Inlet |
| Outlet |
| |
Pressure Pressure |
| |||
| Figure 13 - Millivolt Control Valve | |||
|
|
| To | |
|
|
| Main | |
|
|
| Burner | |
From |
|
| ||
Gas |
| E | A | |
Supply | Inlet | Outlet | ||
Pressure | ||||
|
| |||
|
| Pressure | ||
|
|
| ||
Figure 14 - Electronic Control Valve | ||||
GAS LINE | ||||
| WARNING: Gas line hookup | |||
should be done by your gas | ||||
supplier or a qualified service | ||||
person. |
| |||
| WARNING: Before you pro- | |||
ceed, make sure your gas supply | ||||
is OFF. |
| |||
A manual shutoff valve has been included in the | ||||
applianceʼs gas supply system. You may consider | ||||
installing an extra gas shutoff valve outside the ap- | ||||
plianceʼs enclosure (check with local codes) where | ||||
it can be accessed more conveniently with a key | ||||
through a wall as shown in Figure 15, page 10. | ||||
A 30" long, 1/2" NPT SCHD 40 flexible gas line | ||||
(supplied) may be used between the incoming 1/2" | ||||
NPT black iron gas line and the fireplace regulator | ||||
(located inside the firebox, under the access plate). | ||||
The incoming gas line may be routed toward the | ||||
appliance from either the left or right hand side of | ||||
fireplace outer surround. |
www.desatech.com | 9 |