INTRODUCTION
Models GL36ST/P and GL36STE/EP are decora- tive gas appliances that use a millivolt gas control and piezo pilot or an electronic gas control valve with an electronic ignition system respectively. These systems require a 6",
The 6"
WARNING: This gas appli- ance must not be connected to a chimney flue servicing a solid fuel burning appliance.
Models GL36ST and GL36STE are smooth face units for natural gas only. The GL36STP and GL36STEP are smooth face units for propane/LP gas only. To determine which type of gas your unit is approved and tested for, check the rating plate on the
BEFORE YOU BEGIN
Before beginning the installation of your appli- ance, read these instructions through completely.
This DESA appliance and its approved compo- nents are safe when installed according to this installation manual and are operated as recom- mended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY
CAUSE A FIRE HAZARD!
The DESA warranty will be voided by and DESA dis- claims any responsibility for the following actions :
A) | Modification of the appliance or any of the |
| components manufactured by DESA unless |
| otherwise permitted by DESA. |
B) | Use of any component part not approved by |
| DESA in combination with this appliance. |
C) | Installation and/or operation in a manner other |
| than instructed in this manual. |
This appliance complies with ANSI
WARNING: Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances. You will also need a building permit from your local Building and Safety Commissioner before installing this appliance; otherwise your insurance company may not cover this appliance.
NOTICE: This appliance is not intended to be used as a primary source of heat.
SELECTING LOCATION
To determine the safest and most efficient location for your appliance, you must take into consider- ation the following guidelines:
1.The location must allow for proper clearances (see Clearances, page 6). Note: This decora- tive appliance is not designed for outdoor installation.
2.The location should be in a place where drafts, air conditioning ducts, windows or doors will not affect fireplace heat output.
3.A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a typical
IMPORTANT: All fireplace openings must be located at least 3 feet from facing wall or com- bustible material.
D) The burning of anything other than the type of |
gas approved for use in this gas appliance. |
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANSI/NFPA
Existing
Side
Wall
Projected Wall
The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 or with the current CAN/CGA B149 Installation Codes for Canada.
4" From Opening to Perpendicular Wall
Figure 2 - Typical Two-Sided Fireplace
Installation