Desa CHDV42NR-B, V42P-A, V42N-A, VV42NB(1), VV42PB(1) Pressure Testing Fireplace Gas Connections

Page 20

20

FIREPLACE INSTALLATION

Checking Gas Connections (Cont.)

FIREPLACE INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 33).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fire- place, or using compressed air.

3.Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Equipment

Open

Shutoff

 

Valve

 

Propane/LP

Equipment

Supply Tank

Shutoff

 

Valve

 

Gas Valve

Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace

Closed

Figure 33 - Equipment Shutoff Valve

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fireplace, pages 26 through 28). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 26).

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

For..com

111906-01E

Image 20
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Table of Contents Safety InformationSafety Information Product Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Horizontal HCorner Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Desa 5/8 Pipe & Vent KitsVertical Venting Number DescriptionFireplace Installation Installing Optional Blower AccessoriesModel BK Installation Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Connecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Or servicing. Correct all leaks at oncePressure Testing Fireplace Gas Connections Checking Gas Joints for Propane/LP Gas FireplaceReplace the switch bracket Cleaning Glass Door REMOVING/REPLACING Glass DoorRemoving Louver Panels Removing Glass DoorsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing Embers Installing Log NoInstalling Log No and Log No For Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsON/OFF Series Models Ghrcb and Cghrcb Optional HAND-HELD Remote OperationThermostat Series Models Ghrctb and Cghrctb Operating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Service Hints Technical ServiceSpecifications Parts Under WarrantyIllustrated Parts Breakdown Parts List CHDV42NR-B Description QTYIllustrated Parts Breakdown Burner Assembly for Models CHDV42NR-BAccessories Owners Registration Form Postage Required 111906-01E Warranty Information

V42N-A, VV42NB(1), CHDV42NR-B, VV42PB(1), V42P-A specifications

Desa VV42PB(1), CHDV42NR-B, V42P-A, VV42NB(1), and V42N-A are a collection of innovative heating solutions designed to offer efficient and reliable warmth for various residential and commercial settings. These models represent the advancements in gas fireplace technology, focusing on enhanced performance, energy efficiency, and user-friendly features.

The Desa VV42PB(1) is a prominent model in this lineup, known for its powerful heat output and elegant design. It boasts a large viewing area, allowing the mesmerizing flames to be the focal point of any room. With its adjustable thermostat, users can easily control the temperature, ensuring comfort while optimizing fuel usage.

The CHDV42NR-B model incorporates advanced features such as a remote control for convenient operation and programmable settings that cater to individual heating needs. This model is engineered with a high-efficiency burner system, which maximizes heat while minimizing gas consumption. Its varied flame heights and dancing flames add a dynamic aesthetic touch, making it a stylish addition to any interior.

The V42P-A stands out for its sleek, contemporary design and user-centric functionality. It features a built-in blower system that enhances heat distribution throughout the space, ensuring consistent warmth even in larger areas. Additionally, this model is designed for easy installation with flexible venting options, making it a practical choice for many homeowners.

VV42NB(1) excels in energy efficiency, boasting a notable efficiency rating that translates to lower utility bills for users. Its dual fuel capability allows for versatile fuel choices, giving homeowners the flexibility to switch between natural gas and propane. This adaptability makes it a favorite among those looking to optimize their heating solutions for cost-effectiveness.

Finally, the V42N-A model is characterized by its robust construction and long-lasting durability, ensuring that users receive reliable heating for years to come. This model incorporates user-friendly controls, making it easy for anyone to operate, regardless of their experience with gas fireplace models.

In conclusion, the Desa VV42PB(1), CHDV42NR-B, V42P-A, VV42NB(1), and V42N-A models exemplify the pinnacle of modern heating technology. With their striking designs, efficient heating capabilities, and practical features, they provide homeowners and businesses with comfortable, stylish, and cost-effective heating solutions for any environment.