OPERATING FIREPLACE

For Your Safety Read Before Lighting

Lighting Instructions

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING FIREPLACE

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information above.

2.Open lower louver panel.

3.Disconnect the wire that runs from TH to TPTH from the control valve.

4.Turn off all electric power to the fireplace.

5.Push in gas control knob slightly and turn clockwise to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not re- quire accessing for lighting.

8.Turn gas control knob counterclockwise to “PILOT”.

9.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service techni- cian or gas supplier.

10.Reconnect the wire that runs from TH to TPTH to the control valve.

11.Turn on all electric power to the fireplace.

12.Turn gas control knob counterclockwise to “ON”.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

 

Gas Control

Variable Control Knob

 

 

 

Knob

 

Piezo

 

 

Ignitor

ILOT

IH

O

O

 

P

 

F

N

 

F

 

 

 

 

LO

Figure 52 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to “OFF”.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1. Turn gas control knob clockwise to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 22.)

2.Follow steps 1 through 8 under Lighting Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 14 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door,

page 22).

For..com

111906-01E

Image 26
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Table of Contents Safety InformationSafety Information Product Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Horizontal HCorner Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowVertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Or servicing. Correct all leaks at oncePressure Testing Fireplace Gas Connections Checking Gas Joints for Propane/LP Gas FireplaceReplace the switch bracket Removing Louver Panels Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Glass DoorsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing Embers Installing Log NoInstalling Log No and Log No Operating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsON/OFF Series Models Ghrcb and Cghrcb Optional HAND-HELD Remote OperationThermostat Series Models Ghrctb and Cghrctb Inspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveSpecifications Replacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List CHDV42NR-B Description QTYIllustrated Parts Breakdown Burner Assembly for Models CHDV42NR-BAccessories Owners Registration Form Postage Required 111906-01E Warranty Information

V42N-A, VV42NB(1), CHDV42NR-B, VV42PB(1), V42P-A specifications

Desa VV42PB(1), CHDV42NR-B, V42P-A, VV42NB(1), and V42N-A are a collection of innovative heating solutions designed to offer efficient and reliable warmth for various residential and commercial settings. These models represent the advancements in gas fireplace technology, focusing on enhanced performance, energy efficiency, and user-friendly features.

The Desa VV42PB(1) is a prominent model in this lineup, known for its powerful heat output and elegant design. It boasts a large viewing area, allowing the mesmerizing flames to be the focal point of any room. With its adjustable thermostat, users can easily control the temperature, ensuring comfort while optimizing fuel usage.

The CHDV42NR-B model incorporates advanced features such as a remote control for convenient operation and programmable settings that cater to individual heating needs. This model is engineered with a high-efficiency burner system, which maximizes heat while minimizing gas consumption. Its varied flame heights and dancing flames add a dynamic aesthetic touch, making it a stylish addition to any interior.

The V42P-A stands out for its sleek, contemporary design and user-centric functionality. It features a built-in blower system that enhances heat distribution throughout the space, ensuring consistent warmth even in larger areas. Additionally, this model is designed for easy installation with flexible venting options, making it a practical choice for many homeowners.

VV42NB(1) excels in energy efficiency, boasting a notable efficiency rating that translates to lower utility bills for users. Its dual fuel capability allows for versatile fuel choices, giving homeowners the flexibility to switch between natural gas and propane. This adaptability makes it a favorite among those looking to optimize their heating solutions for cost-effectiveness.

Finally, the V42N-A model is characterized by its robust construction and long-lasting durability, ensuring that users receive reliable heating for years to come. This model incorporates user-friendly controls, making it easy for anyone to operate, regardless of their experience with gas fireplace models.

In conclusion, the Desa VV42PB(1), CHDV42NR-B, V42P-A, VV42NB(1), and V42N-A models exemplify the pinnacle of modern heating technology. With their striking designs, efficient heating capabilities, and practical features, they provide homeowners and businesses with comfortable, stylish, and cost-effective heating solutions for any environment.