Desa V42N-A, CHDV42NR-B, V42P-A Venting Installation Instructions, Installation Precautions

Page 7

VENTING INSTALLATION INSTRUCTIONS

Installation Precautions

7

VENTING INSTALLATION INSTRUCTIONS

NOTICE: Read these instructions completely be- fore attempting installation.

These models are tested and approved for use with DESA (direct- vent) pipe components and terminations.

The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance.

These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines:

When venting system terminates horizontally on an outside wall, you may install a standoff if the termination cap is to be in- stalled directly on a combustible finish such as vinyl, wood, stucco, etc.

Never run the vent downward as this may cause excessive tem- peratures which could cause a fire.

Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11).

Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

NOTICE: Failure to follow these instructions will void the warranty.

INSTALLATION PRECAUTIONS

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting system (Do not cut or alter vent components)

Installation of any component part not manufactured or ap- proved by DESA

Installation other than as instructed by these instructions

WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serv- ing a separate solid fuel burning appliance. Each direct-vent gas appliance must use a separate vent system. Do not use common vent systems.

WARNING: Vent pipe air space clearances to com- bustibles are 1" on all sides except on the horizontal sections, which require 2" clearances from the top of the pipe. Where the termination cap penetrates a com- bustible wall, 1" air space clearance is required.

For morevisit www..com

111906-01E

Image 7
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsNumber Description High Altitude InstallationDesa 5/8 Pipe & Vent Kits Vertical VentingCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationAttaching Speed Control to Firebox Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Or servicing. Correct all leaks at once Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing Log No Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceThermostat Series Models Ghrctb and Cghrctb Optional HAND-HELD Remote OperationON/OFF Series Models Ghrcb and Cghrcb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementParts Under Warranty Replacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown CHDV42NR-B Description QTY Parts ListIllustrated Parts Breakdown CHDV42NR-B Burner Assembly for ModelsAccessories Owners Registration Form Postage Required 111906-01E Warranty Information

V42N-A, VV42NB(1), CHDV42NR-B, VV42PB(1), V42P-A specifications

Desa VV42PB(1), CHDV42NR-B, V42P-A, VV42NB(1), and V42N-A are a collection of innovative heating solutions designed to offer efficient and reliable warmth for various residential and commercial settings. These models represent the advancements in gas fireplace technology, focusing on enhanced performance, energy efficiency, and user-friendly features.

The Desa VV42PB(1) is a prominent model in this lineup, known for its powerful heat output and elegant design. It boasts a large viewing area, allowing the mesmerizing flames to be the focal point of any room. With its adjustable thermostat, users can easily control the temperature, ensuring comfort while optimizing fuel usage.

The CHDV42NR-B model incorporates advanced features such as a remote control for convenient operation and programmable settings that cater to individual heating needs. This model is engineered with a high-efficiency burner system, which maximizes heat while minimizing gas consumption. Its varied flame heights and dancing flames add a dynamic aesthetic touch, making it a stylish addition to any interior.

The V42P-A stands out for its sleek, contemporary design and user-centric functionality. It features a built-in blower system that enhances heat distribution throughout the space, ensuring consistent warmth even in larger areas. Additionally, this model is designed for easy installation with flexible venting options, making it a practical choice for many homeowners.

VV42NB(1) excels in energy efficiency, boasting a notable efficiency rating that translates to lower utility bills for users. Its dual fuel capability allows for versatile fuel choices, giving homeowners the flexibility to switch between natural gas and propane. This adaptability makes it a favorite among those looking to optimize their heating solutions for cost-effectiveness.

Finally, the V42N-A model is characterized by its robust construction and long-lasting durability, ensuring that users receive reliable heating for years to come. This model incorporates user-friendly controls, making it easy for anyone to operate, regardless of their experience with gas fireplace models.

In conclusion, the Desa VV42PB(1), CHDV42NR-B, V42P-A, VV42NB(1), and V42N-A models exemplify the pinnacle of modern heating technology. With their striking designs, efficient heating capabilities, and practical features, they provide homeowners and businesses with comfortable, stylish, and cost-effective heating solutions for any environment.