REPLACEMENT PARTS

34 SPECIFICATIONS SERVICE HINTS TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service De- partment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Customer Service Depart- ment at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA’s technical service web site at

www.desatech.com.

SPECIFICATIONS

 

CHDV32NR

 

 

(V)T32N(R)

(V)T32P(R)

 

 

 

Btu

12,000/18,000 Btu/hr

11,000/17,000 Btu/hr

 

 

 

Gas Type

Natural

Propane/LP

 

 

 

Ignition

Piezo

Piezo

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

 

 

 

Minimum Inlet Supply Pressure

5.5" w.c.

11.0" w.c.

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

Fireplace (Actual size of

 

 

firebox. Measurements do not

32 1/4" x 34 1/2" x 16 5/8"

32 1/4" x 34 1/2" x 16 5/8"

include nailing flanges or

819 x 876 x 422 mm

819 x 876 x 422 mm

standoffs).

 

 

Carton

33 1/2" x 37 1/2" x 17 1/2"

33 1/2" x 37 1/2" x 17 1/2"

 

851 x 953 x 445 mm

851 x 953 x 445 mm

 

 

 

Weight, lbs/kg*

 

 

Fireplace

80 lbs/36 kg

80 lbs/36 kg

Shipping

83 lbs/38 kg

83 lbs/38 kg

 

 

 

*For refractory lined models add 45 pounds.

For..com

111986-01A

Image 34
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationVent Pipe Connections Installing Horizontal Vent Cap Noncombustible Exterior Square Termination Horizontal Termination Configurations17 max Corner and Alternate Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingInstalling Optional Blower Accessories Fireplace InstallationParts Lists for Venting Kits and Components Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Blower Model BKTInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver REMOVING/REPLACING Glass Door Installing Optional Brick Liner Model BL32DCleaning Glass Door Removing Louver PanelsInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoInstalling Logs No and No Operating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsOptional HAND-HELD Remote Operation Manual ModeAuto Thermostatic Mode Thermostat Series Models Ghrctb and CghrctbSafety Features Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersCleaning Maintenance Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveVT32NRB Illustrated Parts BreakdownVT32PRB CHDV32NR Parts List KEY Part Number Description QTYTechnical Service Replacement PartsService Hints SpecificationsOwners Registration Form Postage Required Accessories Warranty Information