Hearth and Home Technologies 42H-B, 42-B Listing and Code Approvals, Appliance Certification

Page 4

1 Listing and Code Approvals

A. Appliance Certification

C. BTU Specifications

MODELS: Dakota 42-B, Dakota 42H-B

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Vented Gas Appliance

STANDARD: ANSI Z21.50-2003—CSA2.22-M2003

This product is listed to ANSI standards for “Vented Gas Fireplaces” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehi- cles”, and “Gas Fired Appliances for Use at High Altitudes”.

B. Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01 and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Section 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

 

Maximum

Orifice Size

Models

Input BTUH

(DMS)

Dakota 42-B (NG)

60,000

25

Dakota 42-B (LP)

53,000

44

D. High Altitude Installations

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang- ing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop- er orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

4

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 • Rev J 11/08

Image 4
Contents What to do if you smell gas This appliance must be installed outsideHot glass will cause burns Congratulations Listing Label Information/LocationTable of Contents High Altitude Installations Listing and Code ApprovalsAppliance Certification Glass SpecificationsGetting Started Design and Installation ConsiderationsMoisture Resistance Inspect Appliance and Components Tools and Supplies NeededAny such action may cause a fire hazard Framing and Clearances Select Appliance LocationFire Risk Fire Risk Odor RiskClearances Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesSecuring and Leveling Appliance Appliance PreparationRemove Logs and Shipping Cover Gas Information Fuel Conversion Gas ConnectionGas Pressure Fire Risk Explosion RiskFire Risk Explosion Risk Asphyxiation Risk Valve Access Lift Out DoorsElectrical Information Intellifire Ignition System WiringShock Risk Finishing FireplaceNoncombustible Facing Diagram Facing MaterialAppliance Setup Clean the ApplianceGrate Assembly Placement Positioning the LogsFront Log SRV727 Reinstall Door Lock Glass AssemblyPlacing Lava Rock Operating Instructions Before Lighting ApplianceFor Your Safety Read Before Lighting Lighting Instructions Lighting the ApplianceFrequently Asked Questions Fire Risk High TemperaturesIssue Solutions After the Appliance is LitSymptom Possible Causes Corrective Actions TroubleshootingIntellifire Ignition System Maintaining and Servicing the Appliance Valve Service and Replacement Tools RequiredGround Wire Maintenance and Service Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference Materials¨ B. Service Parts ListService 11/08Service Parts List 713Log-4036Set Box #3This page intentionally left blank This page intentionally left blank ¨ C. Warranty Hearth & Home Technologies Limited WarrantyWarranty Contact Information
Related manuals
Manual 36 pages 59.15 Kb

42H-B, 42-B specifications

Hearth and Home Technologies has long been a leader in the realm of home heating and comfort solutions, and their 42-B and 42H-B models exemplify this commitment to quality and innovation. These models are designed to meet modern heating needs while providing an aesthetic appeal that enhances any living space.

One of the standout features of the 42-B and 42H-B is their impressive heating capabilities. With a BTU output that can efficiently heat large areas, these units are perfect for homeowners looking to maintain a comfortable environment during the colder months. The ability to generate substantial heat without consuming excessive fuel has made these models a preferred choice among energy-conscious consumers.

In addition to their efficient heating, the 42-B and 42H-B also incorporate advanced venting technologies. These models are designed with flexible venting options, allowing for both direct vent and B-vent installation. This versatility not only simplifies the installation process but also provides homeowners with more options in terms of their heating setup. Whether looking to install in a new build or retrofit an existing space, the 42-B and 42H-B fit seamlessly into various configurations.

Another notable feature of these models is their aesthetic design. Hearth and Home Technologies understands the importance of appearance in maintaining the overall decor of a home. The 42-B and 42H-B come with customizable front options, ensuring that each unit can match the individual style of a home. From traditional to contemporary looks, these models can complement any interior with elegance and charm.

Safety is a top priority for Hearth and Home Technologies, and the 42-B and 42H-B have been designed with several safety features to ensure peace of mind. The units come equipped with a glass front that remains cool to the touch, preventing accidental burns, and advanced safety shutoff mechanisms that activate in the event of a malfunction, ensuring that homeowners can enjoy their heating solutions without worry.

In conclusion, the Hearth and Home Technologies 42-B and 42H-B models combine efficiency, safety, versatility, and style. They offer an exceptional heating experience, making them an attractive option for anyone looking to enhance their home comfort. With their reliable performance and elegant appearance, these units stand as a testament to Hearth and Home Technologies' dedication to quality in the home heating market.