!WARNING

Never lean over the grill cooking area while lighting your gas grill. Keep your face and body a safe distance (at least 18 inches) from the cooking grid surface when lighting your grill by match.

Manually Lighting Your Grill by Match

1.Insert a match into the manual lighting stick.

2.Follow steps 1 through 5 of the Basic Lighting Procedure.

3.Light the match and extend the lighting stick to cooking grid surface.

4. Turn the desired control knob to the HI position setting to release gas. The burner should light immediately.

OFF

IGNITE / HI

LO

!WARNING

Should a “FLASH-BACK” fire occur in/or around the burner tubes, follow the instructions below. Failure to comply with these instructions could result in a fire or explosion that could cause serious bodily injury, death, or property damage.

Shut off gas supply to the gas grill.

Turn the control knobs to OFF position.

Put out any flame with a proper fire extinguisher.

Open grill lid.

Once the grill has cooled down, clean the burner tubes and burners according to the cleaning instructions found on page 18.

If Grill Still Fails To Light

1.Check gas supply and connections for leaks. Check that all wire connections are secure.

2.Repeat basic lighting procedure. If your grill still fails to operate, turn the gas off at source, turn the control knobs to OFF, then check the following:

Misalignment of burner tubes over orifices Correction: Reposition burner tubes over orifices.

Plugged orifice

Correction: Remove burners from grill, carefully lift each burner up and away from gas valve orifice. Remove the orifice from gas valve and gently clear any obstruction with a fine wire. Then reinstall all orifices, burners, and cooking components.

3.If an obstruction is suspected in grill burner valves, please call for repair service at 1-800-913-8999 (English) or 1-800-648-5864 (French) .

4.If the grill still does not light you may need to purge air from the gas line or reset the pressure regulator excess gas flow device. Note: This procedure should be done every time a new LP gas tank is connected to your grill.

To purge air from your gas line and/or reset the pressure regulator excess gas flow device:

Turn all control knobs to the OFF position.

Turn off the gas at the tank valve.

Disconnect pressure regulator from LP gas tank.

Let unit stand for 5 minutes.

Reconnect pressure regulator to the LP gas tank.

Turn the tank valve on slowly until ¼ to ½ open.

Open the grill lid.

Push and turn any control knob to HIGH.

Turn control knobs to HIGH until all the burners are lit

You may start to use the grill

5.If all checks or corrections have been made and you still have questions about operating your gas grill, call the Grill Information Center at 1-800-913-8999 (English) or 1-800-648-5864 (French)

17

Image 17
Contents Kenmore Precautions Table of ContentsKenmore Grill Warranty Proper Placement and Clearance of Grill Burner Flame Check Package Contents List 1pc Preparation Hardware Pack ContentsModel 90109 Parts diagram KEY# Parts Description Quantity Model 90109 Parts ListAssembly Instructions Firebox Assembly Side Burner & Side Shelf Assembly Side Burner Valve Assembly Battery Assembly Grease Cup AssemblyInstalling Cooking Components Congratulations Connecting LP Gas Tank to LP GrillGrill Lighting Instructions for Main Burners Grill Lighting InstructionChecking for LP gas leaks If Grill Still Fails To Light Manually Lighting Your Grill by MatchCleaning and Maintenance Before Calling for Service TroubleshootingFlare-ups Cooking TemperaturesIndirect Cooking FromCanadian Food Inspection Agency Grill Cooking Chart