GAS REQUIREMENTS
Verify the type of gas supply to be used, |
|
| |
either natural or LP, and make sure the |
|
| |
marking on the appliance rating plate |
|
| |
agrees with that of the supply. The rating |
|
| |
plate is located on the inside back wall of |
| Bottom of unit | |
|
| ||
the Grill. Never connect an unregulated | Coupling |
| |
gas line to the appliance. | Threading compound | ||
| |||
1/2 NPT | must be resistant to LP gas | ||
|
| ||
An installer supplied gas | Close |
| |
NIpple |
| ||
must be installed in an easily accessible | Regulator |
| |
location. All installer supplied parts must | 4.0" W.C. | 1/2 NPT | |
| Close | ||
conform to local codes, or in the absence | Adapter 1/2 NPT | NIpple | |
| |||
of local codes, with the National Electrical | to 3/8 flare fitting |
| |
| Installer supplied | ||
Code, ANSI/NFPA |
| ||
Do not put threading | valve must be easily | ||
| accessible* | ||
National Fuel Gas Code, ANSI Z223.1- | compound on these | ||
| |||
threads |
| ||
1988. |
| ||
|
|
All pipe sealants must be an approved type and resistant to the actions of LP gases. Never use pipe sealant on flare fittings. All gas connections should be
made by a competent technician and in accordance with local codes and ordinances. In the absence of local codes, the installation must comply with the national fuel gas code ANSI
TOTAL GAS CONSUMPTION OF THE GRILL WITH ALL BURNERS ON HI:
The appliance and its individual
NATURAL GAS HOOK UP:
Connection: 1/2" NPT male with 3/8" flare adapter. Operating pressure: 4.0" W.C.
Supply pressure: 5" to 14" water column. If in excess of 14" W.C. a step down regulator is required. Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run, and how deep to bury the line. If the gas line is too small, the grill will not function properly. Any joint sealant used must be an approved type and be resistive to the actions of LP gases.