6.Check for leaks by brushing the soap solution on all gas valves, hose connections and fittings. (Shown by the heavy arrows in Fig. 4, 5, and 6) Make sure you generously brush the locations with the soap solution, completely sur- rounding the connections and fittings.

Fig. 5

Fig. 5a

NOTE: After checking the connections and fittings in Figure 5, replace the control panel in the same manner as it was removed. Take special care to be sure the valve ends are inserted into the openings in the burner ends as shown in Figure 5a. If all valve ends do not immediately align with the burner end openings, starting at one end, grasp the tube burner inside the firebox and gently move it until the valve seats in the open end. Also note that the end caps of the control panel skin fit to the outside of the flanges on the firebox as shown in Figure 5a.

Fig. 6

7.If “growing” bubbles appear on any of the connection points, you have detected a gas leak. Immediately close the LP Gas Cylinder valve by turning handle clockwise

a.If leak appears at either end of hose and regulator assembly, retighten the connection at the leak, but do not over-tighten. (NOTE: Only hand tighten at coupling nut in Fig. 3 shown on previous page) Repeat Leak Test.

b.If the leak is coming from the Gas Cylinder, from the valves at the Control Knobs, or if the leak cannot be stopped, do not use the grill. Call Customer Service at 1-800-251-7558. Be sure to have the grill model number and serial number printed on the black label, located on the back edge of the bottom shelf of the cart. . If you need a replacement part under warranty, a proof of purchase will be necessary.

8.Upon completion of leak test, turn all Control Knobs to the “Off” position. Turn the handle on the LP Gas Cylinder clockwise until it stops. Disconnect LP Gas Cylinder by turning coupling nut on regulator in a counterclockwise direction until regulator is released from threaded LP Gas Cylinder nozzle.

9.Place the protective cap over LP Gas Cylinder nozzle.

10.Re-attach the wire leads to the Igniter Button. Replace Control Panel around flanges at Bowl ends and align bolt holes on each side. Replace and retighten all bolts. (Fig. 1)

Image 17
Contents DA N G E R Carbon Monoxide Hazard Tools Required for Assembly Supplied with GrillDescription Packing ListPreparation for Assembly ContentsStep Right Leg Frame Assembly Assembly InstructionsStep Left Leg Frame Assembly Step Wheel Assembly Step Cart Frame AssemblyStep Cylinder Blocking Wire Assembly Step Steel Privacy Panel AssemblyStep Hood/Body To Cart Assembly Step Side Table Assembly Step Side Burner Igniter Wire Connection Step Side Burner Valve AssemblySide Burner Grid Assembly Step Side Burner Control Knob AssemblyStep Bottom Body Panel Assembly Foil Pan/Grease Pan AssemblyStep Battery in Igniter Installation Step Warming Rack / Flavor Activator / Cooking Grid AssemblyLP Gas Cylinder Connecting/Disconnecting the GasUsing Gas LP Hose and Regulator Connecting LP Gas Cylinder Disconnecting LP Gas Cylinder Installation Codes Before Using Your LP Gas GrillSelecting a Location Performing a Leak TestHow to Perform a Leak Test First Time USE and as required Page Off position Lighting the Grill Using the Pulse-Spark IgnitorManual Lighting of the Grill on Manually Lighting the Grill Manually Lighting the Side Burner Lighting the Side BurnerCheck The Flame Manually Lighting the Side Burner Grill Cooking Direct Method Cooking On the Gas GrillIndirect Cooking Roasting Roasting Indirect MethodDirect Cooking on the Grids End of Cooking Session Warming RackCleaning the Grill Care and MaintenanceHow to Clean the Burners Open up Storage Emergencies TroubleshootingSee How to Clean Burners in Care and Maintenance Clean the Burners. See How to Clean Burners in CareMaintenance Important Notice Page Parts Illustration Key Description Quantity Parts ListMeco Corporation Limited Warranty Limited Warranty