Broilmaster P4 Operation Propane & Natural Grills, Checking for Gas Leaks, Air Shutter Adjustment

Page 17

OPERATION - PROPANE & NATURAL GRILLS

Checking for Gas Leaks

Check for gas leaks every time you connect your Broilmaster® propane gas grill to a Propane gas cylinder, when a connected cylinder has not been used recently, or when either a natural or propane grill is being used for the first time.

CAUTION: DO NOT USE AN OPEN FLAME WHEN CHECKING FOR LEAKS. CHECKING FOR LEAKS WITH AN OPEN FLAME MAY LEAD TO A FIRE OR EXPLOSION, RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY.

To check for gas leaks:

1.Use dish washing liquid and a little water to make a soapy solution.

2.Turn OFF the knob on the control panel.

3.Turn ON the gas at the supply or cylinder. A hissing sound indicates a leak. Turn OFF the gas and repair the leak.

4.Apply the soapy water solution to all gas connections.

5.Look for bubbles. Bubbles indicate a leak.

6.If there are bubbles turn OFF the gas and repair the leak.

7.Turn the gas back ON and repeat the above procedures until all leaks are repaired.

Air Shutter Adjustment

The venturi air shutter(s) are preset at the factory so that after five minutes the burner flames are blue with well defined cones. If, after five minutes the flame is yellow, or there is a gap between the burner and the flame, adjust the venturi air shutter as follows:

1.Turn gas OFF and let the burner cool.

2.Loosen shutter set screw

3.Close the air shutter to the minimum opening. Refer to Figure 11.

4.Light the burner, wait five minutes and then carefully open the air shutter until the flame is blue and well defined.

5.Retighten the set screw.

Operating Instructions

Using the Igniter

CAUTION: IF A BURNER FAILS TO LIGHT AFTER 5 SECONDS, TURN THE BURNER OFF FOR 5 MINUTES, TO ALLOW THE GAS TO CLEAR, THEN TRY AGAIN.

1.Turn knob on the grill CLOCKWISE to the OFF position.

2.Turn ON gas at the source.

3.With the grill lid open, push and turn the burner control knob COUNTERCLOCKWISE to Hi.

4.Push and hold the igniter button until the burner lights (approximately 5 seconds).

5.If a burner does not light, turn OFF all gas and refer to the Troubleshooting section of this manual.

Operating Instructions

Using Matches

CAUTION: IF A BURNER FAILS TO LIGHT AFTER 5 SECONDS, TURN THE BURNER OFF FOR 5 MINUTES, TO ALLOW THE GAS TO CLEAR, THEN TRY AGAIN.

1.Turn knob on the grill CLOCKWISE to the OFF position.

2.Turn ON gas at the source.

3.Open the grill lid.

4.Insert a burning long wooden match through the lighter hole on either side of the grill.

5.Turn the burner control knob COUNTERCLOCKWISE to HI.

6.If a burner does not light, turn OFF all gas and refer to the Troubleshooting section of this manual. FIGURE 23.

FIGURE 23

P3, P4

Page 17

Image 17
Contents B100024-1-0502 Premium P GAS GrillP3, P4 Congratulations Table of Contents Parts Diagram P3BL P3HG P3GY P4BL P4HG P4GY Premium P Series Parts ListBefore You Begin Grill AssemblyRecommended Tools Grill MountingsInstalling the Igniter Igniter AssemblyBurner Stabilizing Arm Portable Cart Models OnlyRadiation Shield Installing the BurnerBurner Stabilizing Bracket Lid Stop Securing the BurnerHandle Grid Lifter Installing RacksInstalling Char-Master Briquets Grill Location Propane GAS GrillsGas Type Cylinder RequirementsConnection Requirements Propane Cylinder SafetyCylinder Storage Connecting to Propane Gas Pressure Regulator and Hose AssemblyGas Conversion Natural GAS Grills Operation Propane & Natural Grills Air Shutter AdjustmentChecking for Gas Leaks Operating InstructionsOP E R AT I O N Electrical AccessoriesBefore Cooking PreheatingI N T E N a N C E Problem Cause Solution TroubleshootingP3, P4 Limited Warranty What is not Covered WarrantyForm NO. B100024-1-0502 Broilmaster